GLOBALSAT TR-203A User Manual
Page 13

12
J0
The power capacity for
sending out battery
low alarm report
u8,
percent
15 ~ 100
J1
The power capacity for
power off TR-203
u8,
percent
10 ~ 100
J6
Battery low alarm
report Media
Media type
bit0=SMS
bit1=TCP
bit2=UDP
bit6=Action[0]
bit7=Action[1]
Action=00: report format 0
Action=01: report format 1
Action=10: GPS on
Action=11:
J7
The power capacity for
clear battery low alarm
flag
u8,
percent
10 ~ 100
Battery
J8
Enable/disable TR-203
to automatically power
on when power
capacity is charged to
the capacity of J1
1/0
0=disable
1=enable
O2
Data logger interval
u16, in
seconds
0 ~ 65535
0=disable
Dat
a
logger
OH
Data logger distance
u32, in
meters
0 ~ 4Giga
0=disable
O1
Motion sensor
sensitivity
u16
0 ~ 100
O3
Report format 0
char(32)
Default=SORPZAB27GHKLMN*U!
ON
Report format 1
char(32)
Default=SARN*U!
OG
Enable/ disable data
buffer function
1/0
Default=1
Other setting
O8
Enable/ disable TR-203 1/0
Default=0.