FEATURE PROGRAMMING & OPERATION INSTRUCTIONS

SET SYSTEM INTO PROGRAMMING MODE WITH THE MASTER CODE

IMPORTANT NOTE:
1) DO NOT TURN OFF POWER while the keypad is in Programming Mode. Otherwise, it may cause data lost/error to the

programmed features in the memory.
2) The keypad beeps after power up. Wait 1 minute until the end of the power up delay, then key in the Master Code for

setting the system into programming mode.

3) For the owner’s convenience in programming at the first time, the factory has put a Master Code 0 0 0 0 into the

keypad (It is NOT a default code). To compromise security, in all cases, the owner should program a new Personal

Master Code to invalidate the factory set Master Code after the keypad is owned.

MASTER CODE

The Master Code can be a factory set master code or the private master code that
was set by the owner.

Validate the master code with

* *

.

2-beep confirms a valid master code. The Mains LED (Amber) is constantly ON after the system is set in the
programming mode.

DIRECT ACCESS TO PROGRAMMING MODE WITH THE “DAP” CODE – 8 0 8 0


Set System Into Programming Mode With DAP Code In Case Of The Master Code Is Forgotten ! !
The owner requires to apply the following procedures precisely to set the system into programming mode

with the DAP code 8 0 8 0.

1) Switch OFF all the power for 1 minute to ensure that the system is fully discharged.
2) Swich ON power again. The system is in Power-up Mode for 1 minute and the buzzer gives beeps during the whole

period. This is the only time limit for setting the system to Direct Access to Programming (DAP).

3) Press the Egress Button (EG IN) once first to enable the DAP function.
4) Key in the DAP Code 8 0 8 0 and validate it with

* *

, the existing Master Code in the memory is erased and the

power up beep stops. The keypad turns itself into programming mode like using the Master Code and it is ready to

accept the new programming data.

5) If the Egress Button is not pressed and the DAP code is not keyed in within the power up period, the system will set

itself to normal operation mode. To set it back to power-up mode, repeat procedures 1-4.

DAP CODE

The DAP code is fixed on 8 0 8 0 and it is valid only in the Power-up Period after the Egress Button is pressed.
Validate the DAP code with the

* * .

2-beep confirms the system is in the Programming Mode; and the Mains LED is constantly ON.
See “RECORD A MASTER CODE” at “Location 01” for the details of programming a new master code.

NOTE:

If the keypad is linking up with the DA-2800 or DA-2801 controller in the Split-decoded operation, it is necessary to put

the controller’s “Link-up Jumper” to “ON” position to get the new Master Code for it. As the Master Code is also the

link-up code of the two units. Do Not Forget to put the Link-up jumper back to OFF position after the programming.

0000

8080

**

**

MASTER CODE

VALIDATION

DAP CODE

VALIDATION

EGRESS BUTTON

PRESS ONCE