Velleman HAA2890 User Manual
Page 24
EGRESS DELAY AND WARNING (Location 90)
CONFIGURATIONS OF THE EGRESS WARNING AND ALARM
Key in the number to enable 1, 2, 4 or 5 configurations described below:
1
--- Momentary Contact Mode without Warning -- (Default)
• Press the Button once. No warning or alarm is given during Egress Delay.
• Good for silent area. The people have to wait for the door open until the delay time
reaches.
2
--- Momentary Contact Mode with Warning Beep
• Press the Button once. The system gives Warning Beeps during the Egress Delay.
• Good for the place required attention. The keypad beeps during the people are waiting for
the door open.
4
--- Holding Contact Mode without Warning
• Press and hold the Button. No warning or alarm is given during the Egress Delay.
• Good for the silent area. The people require to press & hold the button until the delay time
reaches for the door open.
5
--- Holding Contact Mode with Warning Beep
• Press and hold the Button. The system gives Warning Beeps during Egress Delay.
• Good for the place required attention. The keypad beeps while the button is kept pressed
during the people are waiting for the door open.
EGRESS DELAY TIMER
0
--- No Delay – (Default)
Output 1 activates instantly (the door is released instantly) when the Egress Button is pressed.
1
–
99
--- Egress Delay Timing
Put any number of 1 to 99 into the box to enable the Egress Delay. The number is the time in second, which starts to
count when the Egress Button is pressed. Output 1 activates (the door is released) when the delay time reaches.
NOTE:
1) Momentary Contact -- The Egress Delay starts to count when the egress button is momentarily pressed. Output 1
activates automatically (door is released) when the delay time reaches.
2) Holding Contact -- The user MUST hold the egress button in contact for the whole period of the Egress Delay time
until Output 1 activates. If the egress button is released before the end of the Egress Delay, the timer will stop to count
and reset.
3) The Egress Delay does not affect the operation of the User PINs/Cards for Output 1. The User PINs/Cards always
give INSTANT action.
EXAMPLES:
Example 1: Set Egress Button in Momentary contact 5 seconds with delay & warning beep
90
2
5
#
(a) (b) (c) (d)
(a) Egress function programming, (b) Momentary contact with warning, (c) Delay time of 5 seconds to release door,
(d) Entry confirmation
FUNCTION MODES
VALIDATION
DELAY TIME
LOCATION
1
,
2
,
4
or
5
0
or
1
-
99
#
90
24
HAA2890_Manual.indd 18
24/05/2012 15:21:13