beautypg.com

Velleman HAA2890 User Manual

Page 19

background image

VISITOR CODES (FOR OUTPUT 1 ONLY) (Location 40)

The Visitor Codes are the temporary user codes for operating of the Output 1 (mainly for door strike in access control).

They can be programmed as “One Time Codes” or “Codes with Time Limit”. The Visitor Codes will be cleared

automatically after use if they are one time codes, or, when the allowed time expires.

VISITOR ID
50 Visitor IDs for storing the codes. They are represented by a
Two-digit ID Number of

01

to

50

.

0999

= Clear all the Visitor Codes from Location 40. Please

see the Programming example below for the details.

VALID PERIOD
The codes in this box MUST be two digits and they represent the time of the operation.

00

--- One Time Code

One Time Code has no time limit but it can only be used for ONCE.

It is cleared by the system automatically after use.

01

-

99

--- Time Limit in Hour(s)

The Visitor Code can be set with the valid time limit of 1 Hour to 99 Hours with a

two-digit number of 01 to 99. The visitor code is cleared by the system when

the time limit reaches.

VISITOR CODES

When a new Visitor Code is put in the same Code box, the old code is replaced.

The Visitor Codes can be 4-8 digits for the Manual Mode code entry.

The Visitor Codes MUST be in the same digit length with the Master Code for Auto Mode code entry.

NOTE: All Visitor Codes will be cleared after power down to prevent extension/confusion of their valid time limit.

EXAMPLES:
Example 1:
Set a “One Time Visitor Code” with the number of “1 2 6 8” for the Output 1

40

01

00

1268

#

(a) (b) (c) (d) (e)

(a) Visitor Code Programming, (b) The Visitor ID, (c) An One Time Code, (d) The Visitor Code, (e) Entry Confirmation

Example 2: Set a “Visitor Code” with the number of “1 3 7 8” that is valid for three hours for the Output 1

40

02

03

1378

#

(a) (b) (c) (d) (e)

(a) Visitor Code Programming, (b) The Visitor ID, (c) Valid for 3 Hours, (d) The Visitor Code, (e) Entry Confirmation

Example 3: Delete a “Visitor Code” from Vistor ID

02

in the memory

40

02 #

(a) (b) (c)

(a) Visitor Code Programming, (b) The Visitor ID, (c) Delete Confirmation

Example 4: Clear all “Visitor Codes” from Location

40

40

0999 #

(a) (b) (c)

(a) Visitor Code Location, (b) The Deletion Command Code, (c) Confirmation, all Visitor Codes are cleared

4-8 DIGITS

40

#

01

-

50

00

or

01

-

99

VISITOR CODE

VALIDATION

LOCATION

VISITOR ID

VALID PERIOD

19

HAA2890_Manual.indd 29

24/05/2012 15:21:14