Example 2: Set Egress Button in Holding contact of 10 seconds with warning beep

90

5

10

#

(a) (b) (c) (d)

(a) Egress function programming, (b) Holding contact mode with warning, (c) Holding time of 10 seconds to release

door, (d) Entry confirmation

Example 3: Set Egress Button in Momentary contact without delay (This is the default setting)

90

1

0

#

(a) (b) (c) (d)

(a) Egress function programming, (b) Momentary contact without delay, (c) Release door instantly, (d) Entry

confirmation

CLOSE THE PROGRAMMING MODE (

* *

)

Always close programming mode with

* *

to set system back to normal Operation after programming.

VALIDATION

**

------------------------------- System is back to normal operation mode