beautypg.com

2 remote commanding via sms message, Sms remote control command table, For 2-digit remote control command – Velleman CTC1000 User Manual

Page 36: System reset

background image

CTC1000

V. 01 – 12/06/2013

36

©Velleman nv

31

UR#2 activate


Example: if the Listen-in communication is activated by DTMF01, no DTMF command can be set for further
operation.

15.2 Remote commanding via SMS message

Remember to change the Language setting of your mobile phone to English before proceeding.

SMS Remote Control Command Table

Control Command

Action

00

hang up with Confirmation

10

disarm

11

arm

20

UR#1 deactivated

21

UR#1 activated

30

UR#2 deactivated

31

UR#2 activated

For 2-digit Remote Control Command
Send the SMS message to command the Unit to enter Arm Mode and send a confirmation SMS back to your
mobile phone. The format is:

M I C H A E L * 1 2 3 4 1

1

0 0

The
programmed
SMS keyword

User pin

Code

Remote

Control
Command


A confirmation SMS message will read on your mobile phone as: Confirmation, MICHAEL* 1234 11 00

Send the SMS message to command the Unit to enter Arm Mode without a confirmation SMS back to your
mobile phone. The format is

M I C H A E L * 1 2 3 4 1

1

The programmed
SMS keyword

User

pin
Code

Remote

Control
Command


The system will automatically filter through all incoming SMS messages for SMS Keyword and automatically
ignores and deletes SMS which does not contain the SMS keyword. For all authorized remote command that
comes with proper keyword and pin code, the system will immediately carry out the contained command(s) and
delete the SMS message afterward.

16. System reset

When resetting the control panel, all programmed parameters (including pin codes) are reset to factory defaults
and all devices are removed. You have to do the programming and add the devices one by one again.
The control panel can clear all programmed parameters by the following sequence:
1. Remove the power supply and remove the backup battery.
2. Apply power while holding down the  key.
3. Release the  key when you hear a tone.

The control panel will display Enter Code.

4. Enter the following key sequence: , OK key
5. Press OK.

If you enter an incorrect key, the unit will revert to normal Alarm On mode.