beautypg.com

Altronix ALTV248UL Series Installation Instructions User Manual

Page 3

background image

ALTV248ULseries

- 3 -

Specifications:

Installation Instructions:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local
codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Mount unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the
enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s
upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the
enclosure. Drill the lower holes and install the three fasteners. Place the enclosure’s upper keyholes over the two
upper screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 11, 12).
Secure enclosure to earth ground.
2. Set power switch on power distribution board marked [PD] to OFF position for models ALTV248UL or

ALTV248ULCB (Figs. 1a, 2a, pg. 5). Set power disconnect circuit breaker to OFF position for all

other models (Figs. 3a-10a, pgs. 6-10).

3. All units are factory set for 24VAC operation.

For 28VAC operation adjust unit prior to mounting and applying power as follows:

Change the wire position so that the wire marked [28V] is connected to the terminal marked [P] and

the wire marked [24V] is connected to the terminal marked [S].

Note: ALTV248ULCB set for 28VAC operation is not Class 2 Rated, not power limited.

4. Connect AC power to the black and white flying leads of the transformer(s) (Figs. 1-10, pgs. 5-10),

secure green lead to earth ground. Use 18 AWG or larger for all power connections.

Keep power limited (PTC protected outputs only) wiring separate from non-power limited wiring.

Minimum 0.25” spacing must be provided. Use separate knockouts.

5. Set power switch on power distribution board marked [PD] to ON position for models ALTV248UL or

ALTV248ULCB (Figs. 1a, 2a, pg. 5). Set power disconnect circuit breaker to RESET (ON) position for

all other models (Figs. 3a-10a, pgs. 6-10).

6. Measure output voltage before connecting devices. This helps avoid potential damage.

Terminals marked [1P - 8P] are of the same polarity.

CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting

the output voltage.

7. Set power switch on power distribution board marked [PD] to OFF position for models ALTV248UL or

ALTV248ULCB (Figs. 1a, 2a, pg. 5). Set power disconnect circuit breaker to OFF position for all

other models (Figs. 3a-10a, pgs. 6-10).

8. Connect devices to terminals marked [1P - 1N through 4P - 4N] on PD4/PD4CB board (Figs. 9, 10, pgs. 9, 10)

or terminals marked [1P - 1N through 8P - 8N] on PD8/PD8CB board (Figs. 1-8, pgs. 5-8), carefully

observing polarity.

9. Set power switch on power distribution board marked [PD] to ON position for models ALTV248UL or

ALTV248ULCB (Figs. 1a, 2a, pg. 5). Set power disconnect circuit breaker to RESET (ON) position for

all other models (Figs. 3a-10a , pgs. 6-10).

10. Green LED will illuminate when power is present.
11. Upon completion of wiring, secure enclosure door with screws (supplied). Installation of cam lock is optional.

Caution: Equipment to be installed/serviced by authorized/trained personnel only.

Shut branch circuit power before installing/servicing equipment.

• UL Listed for Commercial CCTV Equipment (UL 2044).
CUL Listed - CSA Standard C22.2 No.1-98, Audio,
Video and Similar Equipment.
• Surge suppression.
• AC power LED indicator.
• Power ON/OFF switch (ALTV248UL,
ALTV248ULCB).
• Illuminated power disconnect circuit breaker
with manual reset (all other models).
• Unit maintains camera synchronization.
• Ease of installation saves time & eliminates costly labor.

• Spare fuses included (on fuse protected models).

Enclosure Dimensions:

ALTV248UL and ALTV248ULCB:
8.5”H x 7.5”W x 3.5”D
ALTV248300ULM and ALTV248300ULCBM:
8.5”H x 7.5”W x 3.75”D
ALTV248175UL, ALTV248175ULCB,
ALTV248300UL and ALTV248300ULCB:
12”H x 7.75”W x 4.5”D
ALTV248600UL and ALTV248600ULCB:
13.5”H x 13”W x 3.5”D