VEGA VEGASON 66 Foundation Fieldbus User Manual
Page 53
-
Min./max.-adjustment: Level at 'Cal_point_hi'. When writing 'Cal_level_hi' and
'Cal_type' = 1 (Online) the 'Cal_point_hi' is automatically set to the current sensor value.
The unit is defined in 'Level_unit'
l
CAL_LEVEL_LO
-
Min./max.-adjustment: Level at 'Cal_point_lo'. When writing 'Cal_level_lo' and
'Cal_type' = 1 (Online), the 'Cal_point_lo' is automatically set to the current sensor
value. The unit is defined in 'Level_unit'
l
CAL_TYPE
-
Min./max.-adjustment: Defines type of calibration: Dry: no influence of sensor value.
Online: current sensor value determines 'Cal_point_hi/lo'
l
level
-
Value after min./max.-adjustment
l
level_unit
-
Unit code of 'Level', 'Level_offset', 'Cal_level_hi', 'Cal_level_lo'
l
level_offset
-
Offset that is added to the 'Level' value. Unit derives from 'Level_unit'
l
SENSOR_OFFSET
-
Offset that is added to the 'Sensor_value'. Unit derives from 'Sensor_range.unit'
l
end_of_operation_range
-
Set up to suit the process conditions
l
begin_of_operation_range
-
Set up to suit the process conditions
l
product_type
-
Set up to suit the process conditions. If Special-Parameter adjustment has been utilized
this parameter cannot be written
l
liquids_medium_type
-
Set up to suit the process conditions. If Special-Parameter adjustment has been utilized
this parameter cannot be written
l
solids_medium_type
-
Set up to suit the process conditions. If Special-Parameter adjustment has been utilized
this parameter cannot be written
l
liquids_vessel_type
-
Set up to suit the process conditions. If Special-Parameter adjustment has been utilized
this parameter cannot be written
l
solids_vessel_type
-
Set up to suit the process conditions. If Special-Parameter adjustment has been utilized
this parameter cannot be written
l
fast_level_change
-
Set up to suit the process conditions. If Special-Parameter adjustment has been utilized
this parameter cannot be written