beautypg.com

4 technical data – VEGA VEGACOM 557 PC-MODEM - Interface User Manual

Page 9

background image

VEGACOM 557 - without protocol

9

Technical data

4 Technical data

Power supply

Operating voltage

U

nom

= 24 V AC (20 … 53 V), 50/60 Hz or
= 24 V DC (20 … 72 V)

Power consumption

approx. 6 VA

Fuse

1 A, slow-blow

Electrical connection

Component

multiple plug acc. to DIN 41 612, series F
48-pole (d, b, z) with coding holes

Module in carrier
BGT 596 or BGT LOG 571

suitable multipoint connector acc. to DIN 41 612
with connection via standard technologies

Housing type 505

via screw terminals max. 1 x 1,5 mm

2

Indicating elements

LED in front plate

green BA: without function
red (flashing): DISBUS/LOGBUS-failure
red (flashing irregularly): no PC/PLC-outputs
co-ordinated to the measurement loop
red (permanently): failure
green on: operating voltage on

Meas. data input DISBUS

Data transmission

DISBUS (digital data transmission)

Connection line

2-wire standard line (screening recommended)

Line length

max. 1000 m

Meas. data input LOGBUS

Data transmission

LOGBUS (digital data transmission)

Connection line

connection via BUS-plug

PC-interface

Interface standard

RS 232 C

Line length

max. 15 m

Transmission rate in baud

1)

300, 600, 1200, 2400, 4800, 9600, 19200, 38400

Transmission format

1)

8 data bits, 1 Stop bit, no parity or even parity

Plug in the front plate

SUB-D-plug connector, 9-pole, pins

1)

via DIL-switch adjustable on the basic board