beautypg.com

VEGA VEGACOM 557 PC-MODEM - Interface User Manual

Page 10

background image

10

VEGACOM 557 - without protocol

Technical data

Electrical protective measures

Protection:
not mounted

IP 00

in carrier BGT 596
or BGT LOG 571
- front side completely equipped

IP 40

- upper and lower side

BGT 596

IP 00

BGT LOG 571

IP 20

- wiring side

IP 00

in housing type 505
- front side

IP 40

- other sides

IP 30

Protection class

II (in housing type 505)

Overvoltage category

II

Electrical separating measures

Reliable separation acc. to VDE 0106, part 1 between power supply, LOGBUS, DIS-
BUS, PC-connection and appropriate interface

- reference voltage

250 V

- test voltage

2 kV

CE-approval, conformity judgement

VEGACOM 557 meets the protective regulations of EMVG (89/336/EWG) and NSR (73/23/
EWG). The conformity has been judged acc. to the following standards:
EMVG Emission

EN 50 081 - 1: 1993

Susceptibility

EN 50 082 - 2: 1995

NSR

EN 61 010 - 1: 1993

Ambient conditions

Permissible ambient temperature

-20°C … +60°C

Storage and transport temperature

-20°C … +85°C

Humidity

93 %, T = 40°C acc. to DIN/IEC 68-2-3

Shock load

2 … 100 Hz, 0,7 g

Mechanical data

Series

module unit for

- carrier BGT 596
- carrier BGT LOG 571
- housing type 505

Dimensions, unassembled

W = 25,4 mm (5 TE), H = 128,4 mm, D = 166 mm

Weight

approx. 550 g