beautypg.com

Veris Technologies EC Force Probe - Operating Instructions User Manual

Page 27

background image

OM17-P4000 Force/EC

6-3


Probe EC Signal Testing

– The EC – Force probe is shipped with a EC dipole tester

(Part No. 29689) that will enable you to quickly check the probe and instrument to
ensure the EC is functioning correctly. To perform this test, do the following:

1) Press one bolt of the dipole tester to the side of the probe tip and the other to

the center brass dipole. (see figure 5 below) Depending on if the brass or the
silver bolts are used the EC reading will be high or low. The high and low
readings may vary depending on contact with the probe tip and the probe tip
cleanliness. This is fine; the import thing is that the brass reading be lower
than the silver. The difference between the two readings will be hundreds of
EC values.


Figure 4