Veris Technologies EC Force Probe - Operating Instructions User Manual
Page 23
OM17-P4000 Force/EC
5-10
Field Operations
P4000T Removal and Tractor installation
The P4000 is designed to work equally well on a tractor, or as a skid mount unit.
Removing probe from skid
–
- Install three point stabilizer stands into probe and temporarily lock in mid position
with ¾” pinch bolt.
- Extend and unfold the probe.
- Lower foot to ground level.
- Remove fold cylinder pin, and carefully retract fold cylinder until it is fully
retracted. You may have to gently move fold control valve back and forth to
relieve pressure on pin for removal.(Figure 19)
-
Carefully remove lower link pins and lower probe down by retracting foot cylinder
-
Lower stabilizer stands and lock with ¾” bolt
- Retract probe platform and shut of engine. (Figure 20)
- Disconnect wiring and 4 hoses on bottom of console (Figure 21)
- Disconnect main Pressure and Tank hose from platform (Figure 22)
Figure 19 P & T Hoses
Figure 20