beautypg.com

Keep feet clear of foot and probe – Veris Technologies EC Force Probe - Operating Instructions User Manual

Page 17

background image

OM17-P4000 Force/EC

5-4

Field Operation

EC - Force Probe


Checking Electrical Signal Continuity and Electrode Isolation
It is recommended that you routinely check the EC signal to verify that all functions are
working properly. See Maintenance and Lubrication Section for a step-by-step
procedure. It is advisable to perform this test on a routine basis (weekly or every 20-25
hours of data collection) to ensure you are obtaining reliable data.
Operation
Begin field operation by lowering the foot to the soil. Remove hairpin from string pot
piston (Figure 7) Set probe speed --- not recommended over 3cm/sec. This is
adjustable via the probe speed flow control on the side of the control panel. (Figure 9)

Lower the EC - Force Probe until the EC tip is at the desired starting point, usually just
below the surface of the soil. Press LOG in the EC

– Force software to begin collecting

data. After reaching the desired depth pull probe out to stop logging data.

KEEP FEET CLEAR OF

FOOT AND PROBE

.

Figure 7

Figure 8