3000 Series Indicators
3..3 Auto-Zero Tracking
Set	the	automatc	zero	trackng	functonalty.
	 	 	 	 OFF		 	 		 	 =	dsabled.
	 	 	 	 0.5	d			 	 	 =	the	dsplay	wll	mantan	zero	untl	a	drft	of	0.5	dvsons	per	second	has	been		 	 	
	 	 	 	 	 	 	 	 	 	 	 exceeded.
	 	 	 	 1	d		 	 		 	 =	the	dsplay	wll	mantan	zero	untl	a	drft	of	1	dvson	per	second	has	been			 	 	 	
	 	 	 	 	 	 	 	 	 	 	 exceeded.
	 	 	 	 3	d		 	 		 	 =	the	dsplay	wll	mantan	zero	untl	a	drft	of	3	dvsons	per	second	has	been		 	 	 	
	 	 	 	 	 	 	 	 	 	 	 exceeded.
NOTE:	When	the	LFT	menu	tem	s	set	to	ON,	the	selectons	are	lmted	to	0.5d	and	3d.		The	settng	s	
locked	when	the	hardware	lock	swtch	s	set	to	the	ON	poston.
3.. Backlight
Set	the	dsplay	backlght	functonalty.
	 	 	 	 OFF		 	 	 	 =	always	off.
	 	 	 	 ON		 	 		 	 =	always	on.
	 	 	 	 AUtO	 	 		 	 =	turns	on	when	a	button	s	pressed	or	the	dsplayed	weght	changes.		
	 	 	 	 	 	 	 	 	 	 	 turns	off	after	5	seconds	of	no	actvty.
	 	 	 	
3.. Auto Off Timer
Set	the	automatc	shut	off	functonalty.
	 	 	 	 OFF		 	 	 	 =	dsabled	
	 	 	 	 SEt	1			 	 	 =	powers	off	after	1	mnute	of	no	actvty.
	 	 	 	 SEt	2			 	 	 =	powers	off	after	2	mnutes	of	no	actvty.
	 	 	 	 SEt	5			 	 	 =	powers	off	after	5	mnutes	of	no	actvty.
3.. End Readout
Advance to the next menu.
3..2 Filter
Set	the	amount	of	sgnal	flterng.	
	 	 	 	 LO			 	 	 	 =	less	stablty,	faster	stablzaton	tme	(<1	sec.)
	 	 	 	 MEd		 	 	 	 =	normal	stablty,	stablzaton	tme	(<2	sec.)