Assembly, Operation – Bosch GMS 120 Professional User Manual
Page 11
English | 11
Bosch Power Tools
2 609 140 939 | (8.3.12)
Display Elements (see figure A)
a Switched-off audio signal indicator
b Warning-function indicator
c Indication of the object type “Non-metal object”
d Indication of the object type “Non-magnetic metal”
e Indication of the object type “Magnetic metal”
f Indication of the object type “Live conductor”
g Temperature control indicator
h Battery indicator
i Measuring indicator
j Fine scale
k Indication “CENTER”
Technical Data
Declaration of Conformity
We declare under our sole responsibility that the product
described under “Technical Data” is in conformity with the fol-
lowing standards or standardization documents:
EN 61010-1:2010-10, EN 61326-1:2006-05,
EN 301489-3:2002-08, EN 301489-1:2008-04,
EN 300330-1:2010-02, EN 300330-2:2010-02 according
to the provisions of the directives 2011/65/EU,
2004/108/EC, 1999/5/EC.
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
Leinfelden, 02.03.2012
Assembly
Inserting/Replacing the Battery
Alkali-manganese batteries are recommended for the meas-
uring tool.
To open the battery lid 14, press the latch 15 in the direction
of the arrow and fold up the battery lid. Insert the supplied
battery. Pay attention that the polarity is correct, according to
the representation on the inside of the battery lid.
The battery indicator h always indicates the current battery
status:
–
Battery fully charged
–
Battery has 2/3 of its capacity or less
–
Battery has 1/3 of its capacity or less
–
Please change battery
f
If the measuring tool is not used for a long period of
time, the battery must be removed. The battery can cor-
rode or discharge itself over long periods.
Operation
f
Protect the measuring tool against moisture and direct
sun light.
f
Do not subject the measuring tool to extreme tempera-
tures or variations in temperature. In case of large var-
iations in temperature, allow the measuring tool to ad-
just to the ambient temperature before switching it on.
In case of extreme temperatures or variations in tempera-
ture, the accuracy of the measuring tool and the display in-
dication can be impaired.
f
Use or operation of transmitting systems, such as
WLAN, UMTS, radar, transmitter masts or microwaves,
in the close proximity can influence the measuring
function.
Initial Operation
Switching On and Off
f
Before switching the measuring tool on, make sure that
the sensor area 12 is not moist. If required, dry the meas-
uring tool using a soft cloth.
f
If the measuring tool was subject to an extreme tem-
perature change, allow it to adjust to the ambient tem-
perature before switching on.
To switch on the measuring tool, press the On/Off button 5.
To switch off the measuring tool, press the On/Off button 5
again.
When no button on the measuring tool is pressed for approx.
5 minutes and when no objects are detected, the measuring
tool automatically switches off to save the battery.
Switching the Display Illumination On/Off
The display illumination can be switched on/off with display-
illumination button 6.
Switching the Audio Signal On/Off
The audio signal can be switched on/off with the audio signal
button 7. When the audio signal is switched off, indication a
appears on the display.
Digital Detector
GMS 120
Article number
3 601 K81 0..
Maximum scanning depth*
– Ferrous metals
– Non-ferrous metals (copper)
– Live conductors 110–230 V
(voltage applied)**
– Wood
120 mm
80 mm
50 mm
38 mm
Automatic switch-off after approx.
5 min
Operating temperature
–10 °C...+50 °C
Storage temperature
–20 °C...+70 °C
Battery
1 x 9 V 6LR61
Operating life time, approx.
5 h
Weight according to
EPTA-Procedure 01/2003
270 g
Degree of protection
IP 54 (dust and splash
water protected)
*depending on operating mode, material and size of the objects, as well
as material and condition of the base material
**less scanning depth for wires/conductors that are not “live”
f
In terms of accuracy, the measuring result can be inferior in case
of unfavourable surface quality of the base material.
Dr. Egbert Schneider