beautypg.com

Setup, Parameter setup – ACU-RITE Micro-Line T User Manual

Page 8

background image

5

MICRO-LINE

Reference Manual

SETUP

There are 3 to 4 parameters that you can define on your system:

• Display resolution (diS)
• Linear error compensation (LEC)
• Scale count directions (Ct dir)
• Input 3 ON/OFF for international units

Establish each setting the first time you power up the system. You can
change the parameters later by returning to Setup and then using the
ENTER key to scroll to the appropriate category.

Anytime you change the linear error compensation, or count direction
for an axis, the absolute and incremental displays for that axis will be
reset to 0. If you change these settings, you’ll need to reestablish the
datum point.

For international units using 5µm (0.0002”) scales with reference
marks, you will need to recall Datum. See page 32.

When in the SetUp mode, use the CLEAR key when you want to back-
space, restore the previous value or access the previous parameter.

Parameter Setup

MLTmanual.QXD 2/12/02 4:10 PM Page 14

This manual is related to the following products: