beautypg.com

Operation – ACU-RITE Micro-Line T User Manual

Page 17

background image

MICRO-LINE

Reference Manual

OPERATION

14

Using the ABS/INCR key, select the absolute (ABS) mode. Also
check that the proper measurement (inch or mm) is selected.

Using RAD/DIA key, select the Radius mode.

Move the tool to a known point, i.e. the outside diameter of the
workpiece or the face of the workpiece.

Press the ZERO key once for the axis (X or Z) for which you’re
entering a dimension.

Using the keypad, enter the distance from your tool’s current
location to the point you want to establish as the datum. Include a
decimal point (.) and minus (-) sign when necessary.

Press the ZERO key for the other axis, or press ENTER to return
to the DRO display.

To set the datum using an offset:

To set the datum at the tool’s current position:

Position the workpiece in the chuck. Move the tool until
it is positioned at the location where you would like to establish the
datum.

Using the ABS/INCR key, select the absolute (ABS) mode.

Press the X-axis

ZERO

key twice to establish the current X-axis

position as the datum. Repeat for the Z-axis.

If you’re using 5µm (0.0002”) scales (international units only),

MICRO-LINE

can recall your last datum position each time you power

up the system (refer to pg. 32 for the proper procedure).

MLTmanual.QXD 2/12/02 4:10 PM Page 31

This manual is related to the following products: