5 test screen – Zhone Technologies IMACS-200 User Manual
Page 144
5-14
WAN Ports
Model No.
Running Head
WAN port User Screens and Settings
WAN ports
5.3.5
Test Screen
Pressing “t” (Test command) in the WAN port Main Screen brings up the screen shown in
Figure 5-10. From this screen, you can create test situations between WAN ports or between
a single WAN port and data test equipment at a remote site. Table 6-5 lists the actions you can
perform from the bottom line of this screen. Table 6-6 lists the settings controlled on this
screen along with their possible values.
Figure 5-10.Typical WAN port Test Screen
Table 5-5. Test Screen Actions
Table 5-6. WAN port Test Screen Options
Action
Function
Save
Saves changes to settings.
Undo
Returns all settings to the last saved state.
Refresh
Updates certain time-related information fields that are not automatically
updated (i.e., performance and test data).
Insert Err
Allows you to manually insert a single bit error into the data signal. This does
not cause a CRC error.
Clear
Clears the Test Screen and resets all counters to zero.
Main
Returns to the WAN port Main Screen. If changes are made to settings and not
saved, you will be prompted to save or abandon those changes.
Parameter
User Options
Notes
Default
BERT
off mark space 1:1 1:7 3:24 qrss
prb11 prb15 prb20
1
off
SYNC
information only–no user options
BE
information only–no user options
ES
information only–no user options
SES
information only–no user options
CSES
information only–no user options