Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed
temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.
COOLING PERFORMANCE DATA
CONDENSING UNIT MODEL NO.
YHJD
60S41S1
INDOOR COIL MODEL NO.
FC/MC62
CONDENSING
ENTERING AIR
TEMPERATURE
IDCFM
1600
1800
2000
ID
DB
(°F)
80 80
75
80
80
80 80 75
80
80 80 80
75 80 80
ID
WB
(°F)
57 62 62 67 72 57 62 62 67 72 57 62 62 67 72
65
T.C.
54.0 57.1 56.9 62.3 67.6 56.0 57.9 57.8 63.4 69.1 58.0 58.7 58.7 64.4 70.5
S.C.
54.0 51.0 43.4 42.9 34.8 56.0 54.4 45.4 45.0 36.2 58.0 57.7 47.4 47.1 37.6
KW
2.8 2.8 2.8 2.9 2.9 2.8 2.8 2.8 2.9 2.9 2.8 2.8 2.8 2.9 2.9
75
T.C.
51.9 54.1 53.9 59.2 64.5 53.7 54.9 54.8 60.2 65.7 55.5 55.7 55.6 61.2 66.9
S.C.
51.9 49.8 42.0 41.7 33.5 53.7 52.7 44.1 43.8 34.8 55.5 55.6 46.1 45.8 36.2
KW
3.2 3.2 3.2 3.3 3.3 3.2 3.2 3.2 3.3 3.3 3.2 3.2 3.2 3.3 3.3
85
T.C.
49.7 51.1 51.0 56.2 61.4 51.3 51.9 51.8 57.1 62.4 53.0 52.7 52.6 58.0 63.4
S.C.
49.7 48.6 40.7 40.5 32.2 51.3 51.1 42.8 42.5 33.4 53.0 52.7 44.9 44.6 34.7
KW
3.6 3.6 3.6 3.6 3.7 3.6 3.6 3.6 3.7 3.7 3.6 3.6 3.6 3.7 3.7
95
T.C.
47.6 48.1 48.1 53.1 58.3 49.0 48.9 48.8 54.0 59.0 50.4 49.7 49.5 54.8 59.8
S.C.
47.6 47.4 39.3 39.2 30.9 49.0 48.9 41.5 41.3 32.0 50.4 49.7 43.6 43.3 33.2
KW
4.0 4.0 4.0 4.0 4.1 4.0 4.0 4.0 4.1 4.1 4.0 4.0 4.0 4.1 4.1
105
T.C.
44.3 44.6 44.1 48.7 53.5 45.6 45.5 44.6 49.3 54.1 46.8 46.3 45.2 50.0 54.7
S.C.
44.3 44.6 37.6 37.4 29.0 45.6 45.5 39.7 39.4 30.2 46.8 46.3 41.8 41.5 31.3
KW
4.5 4.5 4.5 4.5 4.6 4.5 4.5 4.5 4.5 4.6 4.5 4.5 4.5 4.5 4.6
115
T.C.
41.1 41.3 40.2 44.4 48.9 42.2 42.2 40.6 44.9 49.4 43.3 43.1 41.0 45.3 49.9
S.C.
41.1 41.3 35.9 35.7 27.3 42.2 42.2 37.9 37.7 28.4 43.3 43.1 40.0 39.7 29.5
KW
4.9 5.0 4.9 5.0 5.0 5.0 5.0 4.9 5.0 5.0 5.0 5.0 5.0 5.0 5.0
125
T.C.
37.9 37.9 36.2 40.1 44.3 38.8 38.8 36.5 40.4 44.6 39.8 39.8 36.8 40.7 45.0
S.C.
37.9 37.9 34.2 33.9 25.5 38.8 38.8 36.2 35.9 26.6 39.8 39.8 36.8 37.9 27.7
KW
5.4 5.4 5.4 5.4 5.5 5.4 5.4 5.4 5.4 5.5 5.4 5.4 5.4 5.4 5.5
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Air Handlers
Coils
T.C.
S.C.
KW
AHX60
–
1.06
1.13
1.05
F6FP060
–
1.06
1.09
1.01
MA20D MC62D
1.00
1.00
1.00
MV20D MC62D
1.01
1.01
1.00
Furnaces
Coils
T.C.
S.C.
KW
T*(8,L)X*C20
FC/MC62D
1.05
1.08
0.99
T*9X*D20
FC/MC62D
1.02
1.02
1.02
(
Y
*9C/T*9V)*D20 FC/MC/PC60D
0.99 0.96 0.97
Y
*(8,L)C*C20
FC/MC62D
1.00 0.97 0.96
(
Y
*9C/T*9V)*C20 FC/MC62D
0.99 0.96 0.98