8. When the PRINTHEAD LED flashes, reload the ribbon.
9. Make sure the media sensor is properly positioned.
10. Close the printhead.
11. A media and ribbon sensor profile prints.
NOTE: To return to Auto Calibration, press and hold the PAUSE,
CANCEL, and MODE buttons when you turn on the printer.
5HVHWWLQJ 3ULQWHU 3DUDPHWHUV
5HVHWWLQJ )DFWRU\ 'HIDXOWV
If it is ever necessary to reset all of the factory default values, press and
hold the FEED and PAUSE buttons while turning on the power.
Permanently save these values in memory by pressing the MODE button
four times; the DARKEN, POSITION, and CALIBRATE LEDs flash,
indicating the changes have been saved. To return to printing mode, turn
off and then turn on the printer.
5HVHWWLQJ &RPPXQLFDWLRQV 3DUDPHWHUV
Pressing and holding the FEED, PAUSE, and MODE buttons while
turning on the power resets only the communications parameters to 9600
baud, 8 bit word length, no parity, and 1 stop bit. Permanently save these
values in memory by pressing the MODE button four times; the
DARKEN, POSITION, and CALIBRATE LEDs flash, indicating the
changes have been saved.