0DQXDO &DOLEUDWLRQ

Perform a manual calibration if you are using pre-printed media, if
the printer is in manual calibration mode, or
if the printer does not
auto calibrate.

During this procedure, the media type, label length, media and ribbon
sensor settings, and printing method are determined. Media type is
determined by sensing either continuous or non-continuous media as blank
labels move through the printer. If non-continuous media is sensed, label
length is also calibrated. If ribbon is sensed, the thermal transfer print
method is configured; otherwise, the direct thermal print method is
configured.

The results of this calibration are stored in the printer’s memory and are
retained even if printer power is removed. These parameters remain in
effect until the next calibration is performed.

NOTE: This procedure should only be done once to put the printer
into manual calibration. After that, press the MODE button three
times and the FEED button once if you change media (a label prints
that shows the sensor profile).

NOTE: If the printer is in the Peel-Off mode, the operator must
“catch” the labels as they are peeled away from the backing during
this procedure.

1. Place the head open lever in the open position.

2. Remove the ribbon.

3. Remove approximately 6" of labels from the media roll, enough so

that only the backing material is threaded under the media sensor
when the media is loaded.

4. Reload the media.

5. Press and hold down the PAUSE, FEED, and CANCEL buttons.

6. Turn on the power switch.

7. After the CALIBRATE LED goes out, release the PAUSE, FEED, and

CANCEL buttons.