beautypg.com

Cooling capacity - with air handler coils – York H*RC018 THRU 060 User Manual

Page 6

background image

036-21137-003 Rev. A (1102)

6

Unitary Products Group

- = Not applicable.

COOLING CAPACITY - With Air Handler Coils

UNIT MODEL

AIR HANDLER

COIL

1

MODEL

COOLING

MODEL

ELECTRIC

2

HEAT KW

W

RATED

CFM

NET MBH

SEER

W/O TXV

SEER

WITH TXV

3

EER

TOTAL

SENS.

1 PH 12 SEER AC WITH N1AH / G2FD

H2RC018S06

N1AHB0806

2,5,8,10

17

G2FD024(S,H)17

600

19.6

13.2

12.50

12.50

11.60

H2RC024S06

N1AHB0806

2,5,8,10

17

G2FD024(S,H)17

750

23.6

16.9

12.00

12.00

11.00

N1AHB0806

2,5,8,10

17

G2FD030(S,H)17

750

24.0

17.3

12.00

12.00

11.10

H2RC030S06

N1AHB1206

2,5,8,10

17

G2FD030(S,H)17

1000

30.0

21.3

12.00

12.00

11.00

N1AHB1206

2,5,8,10

17

G2FD036(S,H)17

1000

30.6

21.8

12.25

12.25

11.20

H2RC036S06

N1AHB1206

5,8,10,15,19

17

G2FD036(S,H)17

1200

33.8

23.6

11.50

11.50

10.70

N1AHB1206

5,8,10,15,19

17

G2FD046(S,H)17

1200

35.0

24.4

12.00

12.00

10.90

H2RC042S06

N1AHC1606

5,8,10,15,20

21

G2FD042(S,H)21

1400

41.0

29.3

12.00

-

10.50

N1AHC1606

5,8,10,15,20

21

G2FD048(S,H)24

1400

42.5

30.6

12.00

-

10.75

H2RC048S06

N1AHC1606

5,8,10,15,20

21

G2FD048(S,H)24

1575

46.5

36.0

12.20

12.20

10.90

N1AHD2006

8,10,15,20,25,30

24

G2FD060(S,H)24

1575

48.0

36.4

12.50

12.50

11.10

N1AHD2006

8,10,15,20,25,30

24

G2FD061H24

1575

48.5

34.5

12.50

12.50

11.20

H3RC060S06

N1AHD2006

8,10,15,20,25,30

24

G2FD060(S,H)24

1800

57.5

42.6

-

12.00

10.40

N1AHD2006

8,10,15,20,25,30

24

G2FD061H24

1850

58.0

43.2

-

12.00

10.45

3 PH 12 SEER AC WITH N1AH / G2FD

H1RC036S(25,46)

N1AHB1246

5,8,10,15,18

17

G2FD036(S,H)17

1255

33.6

24.9

--

12.00

10.65

N1AHB1246

5,8,10,15,18

17

G2FD046(S,H)17

1250

34.8

25.8

--

12.00

10.95

N1AHC1646

5,8,10,15,18

21

G2FD048(S,H)21

1600

45.5

33.7

--

12.20

11.20

H1RC048S(25,46)

N1AHD2046

8,10,15,20,25,30

24

G2FD060(S,H)24

1620

47.0

34.8

--

12.50

11.45

N1AHD2046

8,10,15,20,25,30

24

G2FD061H24

1600

47.5

35.2

--

12.50

11.50

H1RC060S(25,46)

N1AHD2046

8,10,15,20,25,30

24

G2FD060(S,H)24

1800

57.5

42.6

--

12.00

10.40

N1AHD2046

8,10,15,20,25,30

24

G2FD061H24

1850

58.0

43.2

--

12.00

10.45

1 PH 12 SEER / N1VS - VARIABLE SPEED

H2RC018S06

N1VSB12

10,15,18

17

G2FD024(S,H)17

650

20.2

13.2

13.75

13.75

12.80

H2RC024S06

N1VSB12

10,15,18

17

G2FD024(S,H)17

725

24.2

16.9

13.35

13.35

12.15

N1VSB12

10,15,18

17

G2FD036(S,H)17

775

25.2

17.8

13.50

13.50

12.50

H2RC030S06

N1VSB12

10,15,18

17

G2FD036(S,H)17

1000

31.0

21.9

13.25

13.25

12.15

N1VSB12

10,15,18

17

G2FD046(S,H)17

1000

32.0

22.3

13.75

13.75

12.55

N1VSB12

10,15,18

17

G2FD046(S,H)17

1000

32.0

22.3

13.75

13.75

12.55

H2RC036S06

N1VSB12

10,15,18

17

G2FD036(S,H)17

1200

34.8

23.6

12.40

12.40

11.35

N1VSB12

10,15,18

17

G2FD046(S,H)17

1210

35.8

24.4

13.00

13.00

11.65

N1VSC16

10,15,18

21

G2FD048(S,H)21

1155

36.8

25.1

13.40

13.40

12.20

H2RC042S06

N1VSC16

10,15,18

21

G2FD048(S,H)21

1400

43.0

30.6

13.00

-

11.55

N1VSC16

10,15,18

21

G2FD048(S,H)21

1590

47.0

30.6

12.80

-

11.40

H2RC048S06

N1VSC16

10,15,18

21

G2FD048(S,H)21

1590

47.0

34.9

12.80

12.80

11.40

N1VSD20

10,15,18,30

24

G2FD060(S,H)24

1560

48.5

36.0

13.25

13.25

11.75

N1VSD20

10,15,18,30

24

G2FD061H24

1560

49.0

36.4

13.30

13.30

11.90

H3RC060S06

N1VSD20

10,15,18,30

24

G2FD060(S,H)24

1780

57.5

42.6

-

12.25

10.65

N1VSD20

10,15,18,30

24

G2FD061H24

1780

58.0

43.2

-

12.40

10.80

1 PH 12 SEER AC / F2RP / RC / FC

4

,

5

H2RC018S06

F2RC/F2FC024

5,8,10

18

-

600

20.0

13.2

12.50

12.50

11.70

F2RP/F2FP024

5,8,10

18

-

600

20.0

13.2

12.50

12.50

11.70

H2RC024S06

F2RC/F2FC024

5,8,10

18

-

750

23.4

17.5

11.50

11.50

10.85

F2RC/F2FC030

5,8,10,15

18

-

750

23.4

17.5

11.50

11.50

10.85

F2RP/F2FP024

5,8,10

18

-

750

23.6

17.5

12.00

12.00

10.90

F2RP/F2FP030

5,8,10,15

18

-

750

24.0

17.9

12.00

12.00

11.10

H2RC030S06

F2RC/F2FC030

5,8,10,15

18

-

1000

29.8

21.5

12.00

12.00

11.00

F2RC/F2FC036

5,8,10,15

21

-

1000

31.0

22.4

12.25

12.25

11.30

F2RP/F2FP030

5,8,10,15

18

-

1000

30.2

22.9

12.00

12.00

11.15

F2RP/F2FP036

5,8,10,15,19

21

-

1000

30.2

23.5

12.00

12.00

11.15

H2RC036S06

F2RC/F2FC036

5,8,10,15

21

-

1200

34.6

26.2

12.00

12.00

10.85

F2RP/F2FP036

5,8,10,15,19

21

-

1200

34.6

26.2

12.00

12.00

10.85

F2RP/F2FP042

5,8,10,15

21

-

1200

34.8

26.3

11.60

11.60

10.70

F2FP048

5,8,10,15,20,25

24

-

1200

35.4

26.7

12.00

12.00

10.90

H2RC042S06

F2RP/F2FP042

5,8,10,15

21

-

1400

40.5

28.9

11.80

-

10.35

F2FP048

5,8,10,15,20,25

24

-

1400

42.5

30.5

12.00

-

10.55

H2RC048S06

F2FP048

5,8,10,15,20,25

24

-

1565

46.5

34.9

11.40

11.40

10.75

F2FP060

5,8,10,15,20,25

24

-

1575

48.0

35.9

11.50

11.50

10.70

F2FV060

8,10,15,20,25

24

-

1560

48.5

35.9

13.20

13.20

11.70

H3RC060S06

F2FP060

5,8,10,15,20,25

24

-

1600

56.5

37.5

-

12.00

10.25

F2FV060

8,10,15,20,25

24

-

1780

57.5

42.6

-

12.30

10.60

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210.
Cooling MBH based on 8

0°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.

1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.

2. Single phase units require single phase 2HK heaters. Three phase units require three phase 2HK heaters.

3. TXV = Thermal Expansion Valve kit required. Use 1TV700 series kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC

.

models. All ratings remain the same.

5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D (Blower on Delay) standard.