Xerox 4112 User Manual
Page 8

8
Section
Specification
Frequency
50/60 Hz single phase
FreeFlow Print Server power cord length
10 feet /3 M
Length of cables (2) connecting the Controller
to the Print Engine
10 feet/3 M
15 feet/5 M
Dedicated use of 15 ampere outlet
Receptacle diagram (XNA only, All others:
Flying-leads)
5-15 R
Power
150 W maximum
NOTE 1: Surge protection is strongly recommended for network controller installations and is the
responsibility of the customer.
NOTE 2: The power source for the network controller must be continuous and not interrupted by
an onsite power failure.
Surge Protection
Xerox recommends protecting the FreeFlow
®
Print Server from surges or spikes in electrical
power that can damage the server and result in extended downtime. In areas that tend to
experience brownouts or blackouts with more frequency, installation of an Uninterruptible Power
Supply (UPS) is suggested. This protection is the responsibility of the customer.
Product Recycling and Disposal
Xerox operates a worldwide equipment take back and reuse/recycle program. Contact your Xerox
sales representative (1-800-ASK-XEROX) to determine whether this Xerox product is part of the
program. For more information about Xerox environmental programs, visit
www.xerox.com/environment
.
Note: This product meets the RoHS standards (Removal of Hazardous Substances) required for
products being installed in the European Union.
Space Requirements
To enable a Xerox Service Representative to safely repair the system, the work area must
measure at least 36 inches (91.44 cm) square around the server.
The work surface of the network controller must not infringe on the space requirements by the
print engine and any attached accessories unless the work surface is a table that has wheels and
can easily be moved.
There must be a minimum of 78 inches (198.12 cm) clearance from the floor to the nearest
overhead obstructions.
All standard Xerox space requirements apply to this installation including overhead, shared, aisle
or hallway, and operator space. The customer is responsible to provide appropriate floor spacing
and placement surface.
Storage and future availability of software that ships with the color server is a customer
responsibility. Xerox personnel do not carry replacement materials.
Note: Power Cords for the DFE are approximately 7.5 feet (2.3 meters). The outbound video
cable to the copier/printer is 16.4 feet (5 meters).
Running Antivirus Software
To date, viruses in the Unix environment have not been an issue and are not considered a threat
to system integrity at this time. Mail has been disabled on the platform as an additional
- 4112-4127 Enterprise Printing System-190 4112-4127 Enterprise Printing System-4619 4112-4127 Enterprise Printing System-6663 4112-4127 Enterprise Printing System-3366 4112-4127 Enterprise Printing System-209 4112-4127 Enterprise Printing System-6682 4112-4127 Enterprise Printing System-3385 4112-4127 Enterprise Printing System-4638