beautypg.com

Environmental requirements, Electrical requirements – Xerox 4112 User Manual

Page 18

background image

18

Environmental Requirements

Environmental Factor

Recommended

Minimum

Maximum

Temperature

70 degrees F (22
Celsius)

50 degrees F
(10 Celsius)

90 degrees F
(32 Celsius)

Humidity

45% RH

15% RH

80% RH

Altitude (above sea level)

0 feet (0 m)

10,000 feet
(3,048 M)

Power Consumption (approximate)
Energy Star (eStar) compliant. See
Power Requirements for more
information

Standby: 375w
Low Power:
120w
Sleep Mode:
13w

Running:
1.92Kw

Noise (Approximate sound pressure
level at operator position)

Standby (dbA)
54.4

Running (dbA)
78.7
Peak (dbA) 81.5

Nominal Voltage

208 VAC

187VAC

254VAC

Heat Output

Standby:
1500 BTU/Hr

50/60 Hz run is
7680 BTU/Hr

NOTE 1: If above 90 Degrees F (32 Celsius), reduced relative humidity is required to maintain the
specific performance.
NOTE 2: For altitudes above 10,000 feet, equipment shutdown rates may increase.

Electrical Requirements

The electrical outlet must be located within 6 feet (1828 mm) to the right of the right rear corner of
the main processor, or no more than 3 feet (914 mm) to the left of the left rear corner of the main
processor (when facing the machine). The outlet/circuit cannot be shared with any other devices
or equipment.

Printer System (Western Hemisphere)

Main
Processor

Optional
Controller

All Feeders and Finishers

(each require a separate electrical
connection)

Nominal
Voltage

208-240 VAC
(+6% to -10%)

100-240 VAC,
single phase (+6%
to -10%)

100-240 VAC, single phase (+6% to
-10%)

Amperage

15

3

15

Cycles

50/60 HZ

50/60 HZ

50/60 HZ

Receptacle
NEMA Part No.

6-15R

5-15R

5-15R

Xerox
Receptacle Part
No.

600S3704

600S3704

Power Cord
Length

8.2 feet/2.5
meters

6 feet/3 meters

10 feet/3 meters

Receptacle
Diagram (North
America only:
All others:
Flying-leads)

Power

150 W maximum

60 W maximum


Compliance:
North America : Energy Star (eStar), Choice, cULus,
Europe: CE, NEMKO, WEEE compliance