Electrical data, Static resistances motor and drive data, Basic units with belt-drive – York Sunline 2000 User Manual

Page 11: Belt-drive blower, Basic units with direct-drive

background image

MODEL

DCE

DCG

POWER
SUPPLY

VOLTAGE

LIMITATIONS

(SEE NOTE 1)

SCROLL

COMPRESSOR

COND.

FAN

MOTOR,

FLA

SUPPLY

AIR

BLOWER

MOTOR,

FLA

MINIMUM

CIRCUIT

AMPACITY

MAX.

FUSE

SIZE,

(SEE NOTE 2)

AMPS

MAX.

HACR

BREAKER

SIZE,

AMPS

MIN.

MAX.

RLA

LRA

036

208/230-1-60
208/230-3-60

460-3-60
575-3-60

187
187
414
518

253
253
504
630

18.0
11.4

6.2
5.0

105.0

90.0
45.0
36.0

1.3
1.3
0.8
0.8

4.4
4.4
2.2
2.2

28.2
20.0
10.8

9.3

45
30
15
15

45
30
15

-

048

208/230-1-60
208/230-3-60

460-3-60
575-3-60

187
187
414
518

253
253
504
630

24.4
14.1

7.1
5.6

140.0
105.0

55.0
44.0

1.3
1.3
0.8
0.8

5.0
5.0
2.2
2.2

36.8
23.9
11.9
10.1

60
35
15
15

60
35
15

-

060

208/230-1-60
208/230-3-60

460-3-60
575-3-60

187
187
414
518

253
253
504
630

28.9
16.0

8.0
6.4

165.0
125.0

67.0
50.0

1.3
1.3
0.8
0.8

6.6
6.6
3.3
3.3

44.0
27.9
14.1
12.1

70
40
20
15

70
40
20

-

072

208/230-3-60

460-3-60
575-3-60

187
414
518

253
504
630

20.3
10.2

8.2

146.0

73.0
58.4

1.3
0.8
0.8

6.8
3.6
3.6

33.5
17.2
14.7

50
25
20

50
25

-

NOTES:

1. Utilization Range “A” in accordance with ARI Standard 110. 2. Dual element, time delay type.

MODEL

DCE

DCG

POWER
SUPPLY

VOLTAGE

LIMITATIONS

(SEE NOTE 1)

SCROLL

COMPRESSOR

COND.

FAN

MOTOR,

FLA

SUPPLY

AIR

BLOWER

MOTOR,

FLA

MINIMUM

CIRCUIT

AMPACITY

MAX.

FUSE

SIZE,

(SEE NOTE 2)

AMPS

MAX.

HACR

BREAKER

SIZE,

AMPS

MIN.

MAX.

RLA

LRA

036

208/230-1-60
208/230-3-60

460-3-60
575-3-60

187
187
414
518

253
253
504
630

18.0
11.4

6.2
5.0

105.0

90.0
45.0
36.0

1.3
1.3
0.8
0.8

5.3
5.3
3.1
3.1

29.1
20.9
11.7
10.2

45
30
15
15

45
30
15

-

048

208/230-1-60
208/230-3-60

460-3-60
575-3-60

187
187
414
518

253
253
504
630

24.4
14.1

7.1
5.6

140.0
105.0

55.0
44.0

1.3
1.3
0.8
0.8

8.6
5.2
2.6
2.0

40.4
24.1
12.3

9.9

60
35
15
15

60
35
15

-

060

208/230-1-60
208/230-3-60

460-3-60
575-3-60

187
187
414
518

253
253
504
630

28.9
16.0

8.0
6.4

165.0
125.0

67.0
50.0

1.3
1.3
0.8
0.8

8.6
6.0
3.0
2.4

46.0
27.3
13.8
11.2

70
40
20
15

70
40
20

-

072

208/230-3-60

460-3-60
575-3-60

187
414
518

253
504
630

20.3
10.2

8.2

146.0

73.0
58.4

1.3
0.8
0.8

7.3
3.7
2.8

34.0
17.3
13.9

50
25
20

50
25

-

NOTES:

1. Rated in accordance with ARI Standard 110, utilization range "A". 2. Dual element, time delay type.

ELECTRICAL DATA

-

Basic Units with Belt-Drive

EXTERNAL STATIC PRESSURE DROP

DESCRIPTION

RESISTANCE, IWG

CFM

1000

1200

1400

1600

1800

2000

2200

2400

2600

2800

3000

Economizer

1, 3

0.07

0.08

0.09

0.11

0.13

0.15

0.17

0.20

0.23

0.26

0.30

Electric Heaters

1

5 - 15 KW

0.04

0.05

0.06

0.07

0.08

0.10

0.12

0.14

0.16

0.19

0.22

20 - 30 KW

0.06

0.07

0.08

0.09

0.11

0.13

0.15

0.17

0.20

0.23

0.26

Bottom Duct Connections

1

0.06

0.07

0.08

0.09

0.10

0.11

0.12

0.14

0.16

0.19

0.22

Cooling Only

2

0.08

0.10

0.12

0.14

0.16

0.18

0.20

0.23

0.26

0.29

0.32

1

Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table.

2

Add these resistance values to the available static resistance in the respective Blower Performance Table.

3

The pressure thru the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation.

STATIC RESISTANCES

MOTOR AND DRIVE DATA

-

Belt-Drive Blower

MODEL

BLOWER

RANGE

(RPM)

MOTOR*

ADJUSTABLE

MOTOR PULLEY

FIXED

BLOWER PULLEY

BELT

HP

RPM

FRAME

SIZE

SERVICE

FACTOR

PITCH

DIA.

(in.)

BORE

(in.)

PITCH

DIA.

(in.)

BORE

(in.)

PITCH

LENGTH

(in.)

DESIG-

NATION

DCE / DCG 036

790 - 1120

1

1

2

1725

56

1.15

2.4 - 3.4

7

8

5.7

1

37.3

A36

DCE / DCG 048

790 - 1120

1

1

2

1725

56

1.15

2.4 - 3.4

7

8

5.7

1

37.3

A36

DCE / DCG 060

850 - 1220

1

1

2

1725

56

1.15

2.4 - 3.4

7

8

5.2

1

37.3

A36

DCE / DCG 072

900 - 1250

1

1

2

1725

56

1.15

2.8 - 3.8

7

8

5.2

1

37.3

A36

*

All motors have solid bases and are inherently protected. These motors can be selected to operate into their service factor because they are located in the moving air, upstream of any heating device.

ELECTRICAL DATA

-

Basic Units with Direct-Drive

530.18-TG1Y

Unitary Products Group

11