beautypg.com

3routine care and adjustment, Cleaning – Zebra Technologies S-300 User Manual

Page 33

background image

3

Routine Care and Adjustment

Cleaning

CAUTION: Use only the cleaning agents indicated below. Zebra Technologies
Corporation will not be responsible for any other fluids being used on this
printer. No lubricants are needed.

Table 1 provides a brief cleaning schedule. Specific cleaning procedures are provided
on the following pages.A Preventive Maintenance Kit (part # 01429) is available from
Zebra. Kit items are also sold separately by the part numbers shown.

Preventive Maintenance Kit

Solvent (Alcohol), 4 oz. bottle (part # 01426)

Applicators, bag of 100 (part # 01427)

Cleaning the Exterior

The exterior surfaces of the Zebra Stripe Printer may be cleaned with a lint-free cloth. Do not
use harsh or abrasive cleaning agents or solvents. If necessary, a mild detergent solution or
desktop cleaner may be used sparingly.

Cleaning the Interior

Remove any accumulated dirt and lint from the interior of the printer using a soft bristle
brush and/or vacuum cleaner. Inspect this area after every roll of media.

AREA

METHOD

INTERVAL

Printhead

Alcohol

After every roll of media (or
500 feet of fanfold media)
when printing direct thermal.
After every roll of ribbon
when printing in the thermal
transfer mode.

Platen Roller

Alcohol

Media Sensor

Air Blow

Media Path

Alcohol

Ribbon Path

Air Blow

Upper Guide Rod (Peel-Off)

Alcohol

After every roll of media.

Platen Guide Rod (Peel-Off)

Alcohol

After every roll of media.

Rewind Power Roller (Peel-Off)

Alcohol

After every roll of media.

Lower Guide Rod (Peel-Off)

Alcohol

After every roll of media.

Cutter
assem-
bly (if
used)

If using continuous
pressure-sensitive media

Adhesive remover,

such as “Goo-

Gone”

After every roll of media or
more often depending upon
your application and media.

If using tagstock or label
backing material only

Alcohol and air

blow

After every 2 or 3 rolls of
media.

Tear-Off/Peel-Off Plate

Alcohol

Once Per Month.

Label Available Sensor

Air Blow

Once Per Six Months.

Table 1 Cleaning Schedule

3