background image

Operation
Accumulated Status, Status, and Fault Registers

48

Operating Manual for RS-232 for XPD Series Power Supply

Table 3.8 Accumulated Status, Status, and Fault Registers

Notes:

1.

All mnemonics can be masked or unmasked.

2.

The error (ERR) bit is reset in the accumulated status, status, and serial poll registers with an
error query (ERR?).

3.

The accumulated status register is cleared with an accumulated status query (ASTS?).

4.

A fault is cleared with a fault query (FAULT?).

Condition

Mnemonic Bit Position Bit Weight

Constant voltage operation

CV

0

1

Constant current operation

CC

1

2

Not used

2

4

Overvoltage protection tripped

OV

3

8

Over temperature protection tripped

OT

4

16

Supply external shutdown active (J21-1)

SD

5

32

Foldback mode operation

FOLD

6

64

Remote programming error

ERR

7

128

Power ON (accumulated status, status
registers only)

PON

8

256

Remote mode (accumulated status, status
registers only)

REM

9

512

AC fail condition

ACF

10

1024

Output fail condition

OPF

11

2048

Sense protection tripped

SNSP

12

4096