Installation and Configuration

Remote/Local Operation

Release 1.2

25

the power supply into local mode, or use the REM OFF command to turn off LLO
and return the power supply to local mode. When you toggle to remote mode from
local mode, the power supply has the same conditions are were last set.

Remote

Enable (REM)

Command

You can use the Remote Enable command to toggle between local mode and
remote mode. The default setting at startup is REM ON. With the remote enable
command set at REM ON, you can return the power supply to remote mode
whenever you send any command from the computer. Any time that you change
from local to remote mode during a session, the output is programmed to turn off,
since the remote mode settings may be different from the local mode settings. Send
the OUT ON command to restore the output.

You can turn off Remote Enable and move power supply control to the front panel
by sending the REM OFF command.To check whether the power supply is remote
enabled, use the REM? query command.

Example:

REM ON

Enable the power supply to be sent into
remote mode

VSET 10;ISET 2

Put the unit into remote operation mode
(Use any command to do this.)