beautypg.com

Xantrex Technology RS232-XPD User Manual

Page 40

background image

Operation
Command Summary

38

Operating Manual for RS-232 for XPD Series Power Supply

Table 3.4 Query Commands

Command

Description

AUXA?

Asks for the state of the set value for the AUXA command

AUXB?

Asks for the state of the set value for the AUXB command

CMODE?

Asks for the power supply’s calibration mode status.

DLY?

Asks for the programmable time delay setting before the supply
reports fault conditions.

ERR?

Asks for the most recent remote programming error which occurred in
the supply since the last time the error query command (ERR?) was
used.

FOLD?

Asks for the supply’s present foldback setting.

HOLD?

Asks for the present hold mode setting.

ID?

Asks for the power supply’s model name and master EPROM version.

IMAX?

Asks for the supply’s soft current limit setting.

IOUT?

Measures the supply’s actual current output.

ISET?

Asks for the supply’s present output current limit setting.

OUT?

Asks for the present enabled/disabled status of the supply’s output.

OVSET?

Asks for the supply’s present over voltage protection limit.

REM?

Asks for the state of remote enable.

ROM?

Asks for the version number of the master and slave EPROMs on the
interface PCB.

VMAX?

Asks for the supply’s soft voltage limit setting.

VOUT?

Measures the supply’s actual voltage output.

VSET?

Asks for the supply’s present output voltage setting.