beautypg.com

Section 2. installation and configuration, Introduction, Initial inspection – Xantrex Technology RS232-XPD User Manual

Page 17: Section 2, Installation, Configuration, Introduction initial inspection

background image

Release 1.2

15

Section 2. Installation and Configuration

Introduction

To use this product, you must have the following equipment:

a compatible model of DC output power supply

serial extender cable (straight through)

computer with an RS-232 interface (serial port)

computer-based communications software package

The RS-232 interface is usually installed at the factory. Your local distributor or
service center can also install the interface, especially for use in a
previously-purchased supply already on site. You must then configure the RS-232
Interface-enhanced supply for your system using the “Basic Setup Procedure” on
page 19. Refer a
lso to Figure 2.1, on page 16, Figure 2.2, on page 17 and Figure 2.3,
on page 18
for drawings of the front panel, the interface subplate, and the RS-232
interface printed circuit board (PCB).

Initial Inspection

On first receiving your unit, perform a quick physical check.

Ensure each package contains a power supply with its RS-232 interface board

installed, and manuals for the power supply and the RS-232 interface. Any

additional parts shipped with the power supply will be identified in the supply's

documentation.

Inspect the unit for any signs of physical damage such as scratches, cracks, or

broken switches, connectors, or displays.

Check the printed circuit board and components if you suspect internal damage.

If the unit is damaged, save all packing materials and notify the carrier immediately.
For additional information, please see the section titled, “Returning Power Supplies
to the Manufacturer” in the manual shipped with your complete unit.

!

CAUTION
If you remove the unit's cover, use proper static control techniques to avoid damage
to static-sensitive components on the printed circuit board.