Command
bit
dec
hex
Function and description
Ref.
6
64
40
When selected with ‘&B0’, DTE speed fixed
at 38400 when the link speed is above 9600.
DTE speed fixed at 9600 if link speed is 7200,
DTE speed follows link speed. When selected
with &B1, DTE speed fixed at current rate
when an ARQ connection is made, when a
non-ARQ connection is made, DTE speed
follows the link speed. (See also S18)
&Bn
7
128
80
Enable UK (Australian, Singapore, Indian,
etc.,) type short-to-short (discontinuous) ring-
back detection.
S45=
dec
0-255
hex
0-FF
Delay during which the CND silence detection
is disabled, in 20 ms units. (See also S46)
+087
S46=
dec
hex
CND silence detection interval
+003
0-255
0-FF
To process the CND, silence must be
detected for the specified interval, in 20 ms
units
S48=
bit
dec
hex
Bit-mapped register
+000
0
1
1
Cause CND information to be reported in raw
format
1
2
2
Enable DATA ONLY mode. Auto-detect
V.34/ZyX/V.32bis/V.22bis/V.23/V.21 Bell
103 when answering. If the connection try
fails, the modem will continuously recycle the
handshaking procedure until the S7 register
times out.
2
4
4
Enable data calling tone (CNG) sending
3
8
8
Reverse the V.23 channel speed. Originate
mode modem speed (Send/Receive) 1200/75;
Answer mode modem speed (Send/Receive)
75/1200
&N12
4
16
10
(Work with &D1 command) DTR ON will
have the modem dial the default number and
DTR OFF will have the modem hang-up and
reset to profile 0. When the modem is idle
(waiting for command), it will not dial any
number when DTR changes from ON to OFF
5
32
20
Enable IS-101 command set. Set this bit to 0
to make voice command compatible with U-
1496
S49=
bit
dec
hex
Bit-mapped register
+006
3-0
0-15
0-FF
Set cellular mode transmit power level -9 to -
24 dBm. (See also S43b2)
7
0
0
For cellular mode only. Modem is installed in
office (Default)
7
128
80
For cellular mode only. Modem is connected
to a mobile phone
S50=
dec
hex
Inactively timer, in 10 second units
+000