Device test, Fold selection and editing – Xerox 2750 User Manual
Page 37
2750 op#4 R3.doc 10-02
Page 4-3
Device test
Accessible only to the Key Operator and technician
Device Test allows the Key Operator or technician to exercise independently several of the
folder’s key functions.
Page 1
1: BRIDGE
DIVERT Diverter solenoid at front of bridge
2: STACK
DIVERT Diverter solenoid at back of bridge
3: UPPER
FLIPPER Upper flipper solenoid
4: LOWER
FLIPPER Lower flipper solenoid
Page 2
1: PULLBACKS
Pullback solenoid
2: SHIFT
WHEELS Both shift solenoids at same time
3: BACKSTOP
Backstop solenoid
4: VERT.
BLADE
Vertical blade solenoid
Page 3
1: HORIZ. BLADE - H Lower crossfold (pocket) blade clutch
2: HORIZ. BLADE - L Non-functional
3: AC
MOTOR
Crossfold roller drive
4: STP SHIFT (L)
Drives crossfold shift system to left (viewed from printer)
Page 4
1: STP SHIFT (R)
Drives crossfold shift system to right (viewed from printer)
2: STP
PULLBACKS Drives both pullback stepper motors
3: COUNTER
Press to increment mechanical counter
4: Quit
Return to the main display
The crossfold stepper motors may be run at the same time as their related solenoids are
energized. For example, select
STP–Shift (L)
to run the shift stepper motor in the left-hand shift
direction, then press
+>
as needed to display
Shift Wheels
. Now press the indicated button to
energize the shift solenoids with the stepper motor still running. Press
+>
again to return to
STP-
Shift (L)
. In a similar way, the pullback stepper motors can also be run at the same time as the
pullback solenoid is energized.
NOTE: Only two solenoids can be energized at any one time. Solenoids automatically time-out
after 15 seconds to prevent over-heating – which can also be caused by repeatedly re-energizing
them without a pause to allow cooling.
Fold Selection and Editing
(Assign folds, Assign handfeeds)
Accessible to the Key Operator and technician
These functions allow the Key Operator to add/delete fold programs, and to modify bookfold
binding margins, etc.
Although there are approximately 70 different fold programs stored in the folder firmware, a given
user will be interested in only a few of them. The most popular programs have been collected into
groups, called Fold Banks, each containing up to 10 programs, see Section 9. The programs
included in each Fold Bank are targeted to the local conventions of a specific geographic market.
Select the appropriate Fold Bank number from the Parameters list under the System Menu. This
action loads the set of programs contained in the Fold Bank to NVRAM, which in turn provides a
program list to the operator’s control panel, and also makes the same list available to the Host
Controller. NOTE: This action loads the handfeed menu as well as the on-line folding menu. Fold
banks can only be changed by the technician.
Once the Fold Bank has been selected, the NVRAM program list available at the operator’s
control panel and the host controller may be edited. This allows programs to be added, or deleted
by the Key Operator to simplify the selections available to the user. But note that the Fold Bank
itself is in firmware and cannot be changed. Editing is confined to the list in NVRAM.