beautypg.com

Passwords, System menu, Communications mode – Xerox 2750 User Manual

Page 36: Jog functions, Parameter viewing and modification

background image

2750 op#4 R3.doc 10-02

Page 4-2

Passwords


Certain menu items displayed on the control panel are password protected for the KEY
OPERATORS and TECHNICIAN ONLY
. Untrained persons adjusting parameters can cause a
great deal of damage to the folder. For each of these, the user will be prompted to enter the
password. Use the number

1

button (

up

) until the appropriate number is reached, then press the

number

3

button (

set/enter

). You now have access until either of two events occurs: Power to the

folder is cycled on/off; or, a 10 minute interval passes with the keypad in the operators fold
selection (default) mode. In either event, the keypad will return to a locked state requiring re-entry
of the password.


System Menu

Page 1
1: Communications

mode

2: Infeed jog Fwd

Jam clearance – drives infeed motor forward

3: Infeed Jog Rev

Jam clearance – drives infeed motor in reverse

4: Parameters
Page 2
1: Device

Test

2: Assign

folds

3: Assign

handfeeds

4: Recent

errors

Page 3
1: Stack

sensor

2: Quit

Communications mode

Page 1
1: NORMAL = Normal printer/folder communications
2: USE KEYPAD FOLDS = Overrides Controller fold selections, but maintains communications

(e.g., for job recovery)

3: NONE = Serial port disconnected (comms OFF)
4: LOOPBACK

TEST

=

Communications test

Page 2
1: Quit

Jog functions

These are accessible to the operator - no password required.

Parameter viewing and modification

Viewing - unrestricted access
Modification - technician only

The Key Operator Password can be obtained from your service technician.

Substitutes for an LED. Displays the status of the photosensor at the tower exit: 1
= open (no paper present), 0 = covered (paper detected).