Scanteam 3400pdf product specifications, Environmental specifications, Electrical specifications – Welch Allyn SCANTEAM 3400PDF User Manual
Page 75

7–1
SCANTEAM 3400PDF User’s Guide
Operating Voltage
Current Draw (3400PDF/HD–2, –3)
Current Draw (3400PDF/LR–2, –3)
Standby Current
(3400PDF/HD)
(3400PDF/LR
In–Rush Current
Power Supply Noise Rejection
Acquisition Time (Trigger to Output)
Mean Time Between Failure (MTBF)
Agency Compliance
Patents
5 VDC
±
10%
N/A
280mA
240mA
N/A
3mA
115mA
400mA maximum
100mV peak to peak,
from 10 to 100KHz
100msec maximum
50,000 hours (for ground benign)
FCC Class A, CE (Class A), LVD
U.S. 5,420,409
U.S. 5,723,853
parameter
specification
113 Scans/Sec 200 Scans/Sec
5VDC Input
only
SCANTEAM 3400PDF Product Specifications
Sectio 7
Product Specifications
Environmental Specifications
Operating Temperature
Storage Temperature
Humidity
Barometric Pressure
Mechanical Shock
ESD Sensitivity
Ambient Illumination
Modular Connector Life
32
°
F to 122
°
F [0
°
C to 50
°
C]
–40
°
F to 158
°
F [–40
°
C to 70
°
C]
0% to 95% RH noncondensing
101,000 to 69,000 Pascals
[Sea level to 3,000 meters]
Functional after ten 5ft. [1.5m] drops
Functional after 15KV discharge
3400PDF/HD = 10,000 lux
750 insertions / disconnections
parameter
specification
Electrical Specifications