beautypg.com

Operating instructions, Cgi, cgs, Spark-ignited pilot – Weil-McLain CGa User Manual

Page 21

background image

User’s Information Manual

1

Part Number 550-110-592/0408

• Do not try to light any appliance.

• Do not touch any electric switch; do not use any

phone in your building.

• Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

A. This appliance does not have a pilot. It is equipped

with an ignition device which automatically lights

the burner.

Do not

try to light the burner by

hand.

B.

BEFORE OPERATING

, smell all around the

appliance area for gas. Be sure to smell next to the

floor because some gas is heavier than air and will

settle on the floor. See below.

C. Use only your hand to turn the gas control knob. Never use

tools. If the knob will not turn by hand, don’t try to repair it,

call a qualified service technician. Force or attempted repair

may result in a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the

appliance and to replace any part of the control system and any

gas control, which has been under water.

1.

STOP !

Read the safety information above on this label.

. Set the thermostat to lowest setting.
. Turn off all electrical power to the appliance.
. Remove jacket front panel.
. This appliance is equipped with an ignition device which automatically lights the burner.

Do not try to light the burner by hand.

. Turn

Gas control knob

clockwise

to

OFF

.

. Wait five () minutes to clear out any gas. Then smell for gas, including near the floor.

If you smell gas,

STOP !

Follow

B

in the safety information above. If you don’t smell

gas, go to the next step.

. Turn

Gas control knob

counterclockwise

to

On

.

. Turn on all electric power to the appliance.
10. Set thermostat to desired setting.

11. If the appliance will not operate, follow the instructions

TO TURn OFF GAS TO

APPLIAnCE

below and call your service technician or gas supplier.

1. Replace jacket front panel.

1. Set the thermostat to lowest setting.
. Turn off all electric power to the appliance if service is to

be performed.

Operating instructions

• Spark-ignited pilot

CGi, CGs

Gas valve Honeywell VR8204/VR8304, White-Rodgers 36C and 36E

. Remove jacket front panel.
. Turn

Gas control knob

clockwise

to

OFF

.

Do not force.

. Replace jacket front panel.

FOR YOUR SAFETY READ BEFORE OPERATING

OPERATING INSTRUCTIONS

If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS

TO TURN OFF GAS TO THE APPLIANCE