beautypg.com

Lighting instructions, Standing pilot • gas valve — robertshaw 7000erhc – Weil-McLain CGa User Manual

Page 15

background image

User’s Information Manual

1

Part Number 550-110-592/0408

• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in

your building.

• Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

1.

STOP!

Read the safety information above on this label.

. Set the thermostat to lowest setting.
. Turn off all electrical power to the appliance.
. Remove front panel.
. Depress gas control knob slightly and turn clockwise

to

“OFF”

. Note: Gas control knob cannot be turned to

“OFF”

unless knob is depressed slightly. Do not force.

1. Set the thermostat to lowest setting.
. Turn off all electric power to the appliance if service is to

be performed.

. Remove front panel.

. Depress gas control knob slightly and turn clockwise

to

“OFF”

.

. Replace front panel.

. Wait five () minutes to clear out any gas. Then smell for

gas, including near the floor. If you smell gas,

STOP!

Follow

“B”

in the safety information above.

If you don’t smell gas, go to the next step.

. Remove access panel located above burners.

. Find pilot — follow metal tube from gas con-

trol. The pilot is between two burners behind

the access panel.

Lighting instructions

• Standing pilot

Gas valve Robertshaw 7000ERHC

A. This appliance has a pilot, which must be lighted

by hand. When lighting the pilot, follow these

instructions exactly.

B.

BEFORE LIGHTING

, smell all around the

appliance area for gas. Be sure to smell next to the

floor because some gas is heavier than air and will

settle on the floor. See below.

C. Use only your hand to depress or turn the gas control knob. Never

use tools. If the selector arm will not depress or move by hand, don’t

try to repair it, call a qualified service technician. Force or attempted

repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the appliance

and to replace any part of the control system and any gas control,

which has been under water.

EG-75, EGH-85, EGH-95,

PFG-6, PFG-7

. Turn gas control knob counterclockwise

to

“PILOT”

.

10. Depress gas control knob and hold. Immediately light the

pilot with a match. Continue to hold gas control knob in
for about one (1) minute after the pilot is lit.
• If pilot can be lit without depressing gas control knob,

turn gas knob clockwise

to

“OFF”

and call your

service technician or gas supplier.

11. Release gas control knob. Pilot should remain lit. If pilot

goes out, repeat steps through 11.
• If gas control knob stays depressed after release, stop

and immediately call your service technician or gas

supplier.

• If the pilot will not stay lit after several tries, turn the

gas control knob clockwise

to

“OFF”

and call

your service technician or gas supplier.

1. Replace access panel.
1. Turn gas control knob counterclockwise

to

“ON”

.

1. Turn on all electric power to the appliance.
1. Set thermostat to desired setting.
1. Replace front panel.

550-223-081(0706)

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS

TO TURN OFF GAS TO THE APPLIANCE