beautypg.com

Lighting instructions, Gas valve — robertshaw 7200, Standing pilot – Weil-McLain CGa User Manual

Page 14

background image

CGa, CGi, CGs, EG, EGH, LGB, PEG, PFG Boilers

1

Part Number 550-110-592/0408

Gas valve Robertshaw 7200

• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in

your building.

• Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

A. This appliance has a pilot, which must be lighted

by hand. When lighting the pilot, follow these

instructions exactly.

B.

BEFORE LIGHTING

, smell all around the

appliance area for gas. Be sure to smell next to the

floor because some gas is heavier than air and will

settle on the floor. See below.

C. Use only your hand to depress the selector arm. Never use tools. If

the selector arm will not move by hand, don’t try to repair it, call a

qualified service technician. Force or attempted repair may result in

a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the appliance

and to replace any part of the control system and any gas control,

which has been under water.

1.

STOP!

Read the safety information above on this label.

. Set the thermostat to lowest setting.
. Turn off all electrical power to the appliance.
. Remove front panel.
. Depress and move selector arm left

to

“OFF”

.

Note: Selector arm cannot be moved to

“OFF”

unless

selector arm is depressed slightly. Do not force.

1. Set the thermostat to lowest setting.
. Turn off all electric power to the appliance if service is to

be performed.

. Remove front panel.
. Depress and move selector arm left

to

“OFF”

.

Do not force.

. Replace front panel.

. Wait five () minutes to clear out any gas. Then smell for

gas, including near the floor. If you smell gas,

STOP!

Follow

“B”

in the safety information above. If you don’t smell gas,

go to the next step.

. Remove access panel located above burners.

. Find pilot - follow metal tube from gas con-

trol. The pilot is between two burners behind
the access panel.

. Move selector arm on gas control right

to

“SET”

position.

Lighting instructions

• Standing pilot

CGa-25 to CGa-6,

EG-30 to EG-50,

PEG-30 to PEG-50

10. Hold selector arm in

“SET”

position and immediately

light the pilot with a match. Continue to hold selector arm
to

“SET”

for about one-half (

1

/

) minute after the pilot is

lit.

11. Release selector arm. If pilot does not remain lit, repeat

steps through 1.
• If the pilot will not stay lit after several tries, move

selector arm left

to

“OFF”

and call your service

technician or gas supplier.

1. Replace access panel.
1. Turn selector arm left

to

“ON”

.

1. Turn on all electric power to the appliance.
1. Set thermostat to desired setting.
1. Replace front panel.

550-223-039(0906)

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS

TO TURN OFF GAS TO THE APPLIANCE