beautypg.com

Lighting instructions, End-of-season shutdown, Follow boiler shutdown procedure – Weil-McLain CGa User Manual

Page 12: Propane gas odorant

background image

CGa, CGi, CGs, EG, EGH, LGB, PEG, PFG Boilers

1

Part Number 550-110-592/0408

Follow boiler shutdown procedure

End-of-season shutdown . . . . . . . .

1. Follow “

TO TURN OFF GAS TO APPLIANCE

” on the

Lighting/Operating instructions

on the inside of

the jacket panel. You will also find these instructions

on pages 1 through of this manual.

Use the

Lighting/Operating instruction

for the gas

valve model installed on the boiler.

. Do not drain system unless exposure to freezing

temperatures will occur.

. Do not drain the system if it is filled with an

antifreeze solution.

. Do not shut down boilers used for domestic water

heating. They must operate year-round.

Propane boilers only

— Your propane supplier mixes an odorant with the propane to make its presence detect-

able. In some instances, the odorant can fade and the gas may no longer have an odor.
• Propane gas can accumulate at floor level. Smell near the floor for the gas odorant or any unusual odor.

If you suspect a leak, do not attempt to light the pilot.

• Use caution when attempting to light the propane pilot. This should be done by a qualified service

technician, particularly if pilot outages are common.

• Periodically check the odorant level of your gas.
• Inspect boiler and system at least yearly to make sure all gas piping is leak-tight.
• Consult your propane supplier regarding installation of a gas leak detector. There are some products on

the market intended for this purpose. Your supplier may be able to suggest an appropriate device.

Propane gas odorant

Table 2

Lighting

/Operating

instruction

guide

Standing pilot

Models

Page Spark-ignited pilot

Models

Page

Honeywell VR8200/VR8300

CGa-25 – CGa-8
EG-30 – EG-65
PEG-30 – PEG-55

13

Honeywell VR8204/VR8304

CGa-25 – CGa-8
EG-30 – EG-75
PEG-30 – PEG-55
PFG-5

16

CGi, CGs

21

White-Rodgers 36E

CGa-25 – CGa-6
EG-30 – EG-50
PEG-30 – PEG-50

17

Robertshaw 7200

CGa-25 – CGa-6
EG-30 – EG-50
PEG-30 – PEG-50

14

CGi
CGs

21

Robertshaw 7000ERHC

EG-75
EGH-85, EGH-95
PFG-6, PFG-7

15

White-Rodgers 36C

CGa-7, CGa-8
EG-55 – EG-75
PEG-55, PFG-5

18

CGi, CGs

21

Robertshaw 7200

CGa-25 – CGa-6
EG-30 – EG-50
PEG-30 – PEG-50

19

Robertshaw 7000 DERHC

EGH-85 – EGH-125
PFG-6 – PFG-8

20

--

LGB

22

Lighting instructions

Use

Table 2

below to locate the correct Lighting/Operating instruction for the gas valve model installed on your

boiler.