Lighting instructions – Weil-McLain CGa User Manual
Page 13
User’s Information Manual
1
Part Number 550-110-592/0408
Lighting instructions
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
A. This appliance has a pilot, which must be lighted
by hand. When lighting the pilot, follow these
instructions exactly.
B.
BEFORE LIGHTING
, smell all around the
appliance area for gas. Be sure to smell next to the
floor because some gas is heavier than air and will
settle on the floor. See below.
C. Use only your hand to push down the reset button or turn the gas
control knob. Never use tools. If the knob or reset button will not
operate by hand, don’t try to repair it, call a qualified service techni-
cian. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control,
which has been under water.
1.
STOP!
Read the safety information above on this label.
. Set the thermostat to lowest setting.
. Turn off all electrical power to the appliance.
. Remove front panel.
. Turn gas control knob clockwise
to
“OFF”
.
1. Set the thermostat to lowest setting.
. Turn off all electric power to the appliance if service is to
be performed.
. Remove front panel.
. Turn gas control knob clockwise
to
“OFF”
.
. Replace front panel.
. Wait five () minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas,
STOP!
Follow
“B”
in the safety information above. If you don’t smell gas,
go to the next step.
. Remove access panel located above burners.
. Find pilot - follow metal tube from gas control.
The pilot is between two burners behind the access
panel.
. Turn gas control knob counterclockwise
to
“PILOT”
.
10. Push in red reset button and hold. Immediately
• Standing pilot
•
Gas valve — Honeywell VR8200/VR8300
light the pilot with a match. Continue to hold reset button
in for about one (1) minute after the pilot is lit.
11. Release reset button. Pilot should remain lit. If pilot goes
out, repeat steps through 1.
• If reset button stays depressed after release, stop
and immediately call your service technician or gas
supplier.
• If the pilot will not stay lit after several tries, turn the
gas control knob clockwise
to
“OFF”
and call your
service technician or gas supplier.
1. Replace access panel.
1. Turn gas control knob counterclockwise
to
“ON”
.
1. Turn on all electric power to the appliance.
1. Set thermostat to desired setting.
1. Replace front panel.
CGa, EG-30 to EG-65,
PEG-30 to PEG-55
550-223-038(0906)
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
WHAT TO DO IF YOU SMELL GAS
TO TURN OFF GAS TO THE APPLIANCE