beautypg.com

Lighting instructions – Weil-McLain CGa User Manual

Page 13

background image

User’s Information Manual

1

Part Number 550-110-592/0408

Lighting instructions

• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in

your building.

• Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

A. This appliance has a pilot, which must be lighted

by hand. When lighting the pilot, follow these

instructions exactly.

B.

BEFORE LIGHTING

, smell all around the

appliance area for gas. Be sure to smell next to the

floor because some gas is heavier than air and will

settle on the floor. See below.

C. Use only your hand to push down the reset button or turn the gas

control knob. Never use tools. If the knob or reset button will not

operate by hand, don’t try to repair it, call a qualified service techni-

cian. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the appliance

and to replace any part of the control system and any gas control,

which has been under water.

1.

STOP!

Read the safety information above on this label.

. Set the thermostat to lowest setting.

. Turn off all electrical power to the appliance.

. Remove front panel.

. Turn gas control knob clockwise

to

“OFF”

.

1. Set the thermostat to lowest setting.
. Turn off all electric power to the appliance if service is to

be performed.

. Remove front panel.
. Turn gas control knob clockwise

to

“OFF”

.

. Replace front panel.

. Wait five () minutes to clear out any gas. Then smell for

gas, including near the floor. If you smell gas,

STOP!

Follow

“B”

in the safety information above. If you don’t smell gas,

go to the next step.

. Remove access panel located above burners.

. Find pilot - follow metal tube from gas control.

The pilot is between two burners behind the access
panel.

. Turn gas control knob counterclockwise

to

“PILOT”

.

10. Push in red reset button and hold. Immediately

• Standing pilot

Gas valve Honeywell VR8200/VR8300

light the pilot with a match. Continue to hold reset button

in for about one (1) minute after the pilot is lit.

11. Release reset button. Pilot should remain lit. If pilot goes

out, repeat steps through 1.
• If reset button stays depressed after release, stop

and immediately call your service technician or gas

supplier.

• If the pilot will not stay lit after several tries, turn the

gas control knob clockwise

to

“OFF”

and call your

service technician or gas supplier.

1. Replace access panel.
1. Turn gas control knob counterclockwise

to

“ON”

.

1. Turn on all electric power to the appliance.
1. Set thermostat to desired setting.
1. Replace front panel.

CGa, EG-30 to EG-65,

PEG-30 to PEG-55

550-223-038(0906)

FOR YOUR SAFETY READ BEFORE LIGHTING

LIGHTING INSTRUCTIONS

If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS

TO TURN OFF GAS TO THE APPLIANCE