Operating instructions – Weil-McLain CGa User Manual
Page 20
CGa, CGi, CGs, EG, EGH, LGB, PEG, PFG Boilers
0
Part Number 550-110-592/0408
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
1.
STOP!
Read the safety information above on this label.
. Set the thermostat to lowest setting.
. When equipped with Effikal vent damper Model RVGP, place service switch in Hold
Damper Open position.
. Turn off all electrical power to the appliance.
. Remove front panel.
. When equipped with
Johnson Controls vent damper Model M35, manually rotate
damper blade indirection of arrow to
“OPEN”
position indicated on damper assembly.
. Turn gas control knob clockwise
to
“OFF”
.
. When equipped with vent damper, verify damper blade is in full open position.
. Wait five () minutes to clear out any gas. Then smell for gas, including near the floor.
If you smell gas,
STOP!
Follow
“B”
in the safety information above. If you don’t smell
gas, go to the next step.
10. Turn gas control knob counterclockwise
to
“ON”
.
11. Turn on all electric power to the appliance.
1. When equipped with Effikal vent damper, place service switch in Automatic Operation
position.
1. Set thermostat to desired setting.
1. If the appliance will not operate, follow the instructions
“
TO TURn OFF GAS TO
APPLIAnCE
”
below and call your service technician or gas supplier.
1. Replace front panel.
1. Set the thermostat to lowest setting.
. Turn off all electric power to the appliance if service is to
be performed.
. Remove front panel.
. Turn gas control knob clockwise
to
“OFF”
.
. Replace front panel.
Operating instructions
• Spark-ignited pilot
•
Gas valve — Robertshaw 7000DERHC
A. This appliance is equipped with an ignition device
which automatically lights the pilot.
Do not
try
to light the pilot by hand.
B.
BEFORE OPERATING
, smell all around the
appliance area for gas. Be sure to smell next to the
floor because some gas is heavier than air and will
settle on the floor. See below.
C. Use only your hand to turn the gas control knob. Never use tools. If
the selector arm will not depress or move by hand, don’t try to repair
it, call a qualified service technician. Force or attempted repair may
result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance
and to replace any part of the control system and any gas control,
which has been under water.
EGH-85 to EGH-125,
PFG-6 to PFG-8
FOR YOUR SAFETY READ BEFORE OPERATING
OPERATING INSTRUCTIONS
If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
WHAT TO DO IF YOU SMELL GAS
TO TURN OFF GAS TO THE APPLIANCE
550-223-045(1101)