beautypg.com

Operating instructions, Spark-ignited pilot • gas valve — robertshaw 7200 – Weil-McLain CGa User Manual

Page 19

background image

User’s Information Manual

1

Part Number 550-110-592/0408

• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in

your building.

• Immediately call your gas supplier from a neighbor’s phone.

Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

A. This appliance is equipped with an ignition device

which automatically lights the pilot.

Do not

try

to light the pilot by hand.

B.

BEFORE OPERATING

, smell all around the

appliance area for gas. Be sure to smell next to the

floor because some gas is heavier than air and will

settle on the floor. See below.

C. Use only your hand to depress or move the selector arm. Never use

tools. If the selector arm will not depress or move by hand, don’t try to

repair it, call a qualified service technician. Force or attempted repair

may result in a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the appliance

and to replace any part of the control system and any gas control,

which has been under water.

1.

STOP!

Read the safety information above on this label.

. Set the thermostat to lowest setting.
. Turn off all electrical power to the appliance.
. Remove front panel.

. This appliance is equipped with an ignition device which

automatically lights the pilot.

Do not

try to light the pilot

by hand.

. Depress and move selector arm left

to

“OFF”

.

Note:

Selector arm cannot be moved to

“OFF”

unless selector

arm is depressed slightly. Do not force.

1. Set the thermostat to lowest setting.
. Turn off all electric power to the appliance if service is to

be performed.

. Remove front panel.

. Depress and move selector arm to

“OFF”

. Do not force.

. Replace front panel.

. Wait five () minutes to clear out any gas. Then smell for

gas, including near the floor. If you smell gas,

STOP!

Follow

“B”

in the safety information above. If you don’t smell gas,

go to the next step.

. Move selector arm right

to

“ON”

.

1. Turn on all electric power to the appliance.

10. Set thermostat to desired setting.

11. If the appliance will not operate, follow the instructions

“To Turn Off Gas To The Appliance”

and call your service

technician or gas supplier.

1. Replace front panel.

Operating instructions

• Spark-ignited pilot

Gas valve Robertshaw 7200

CGa-25 to CGa-6,

EG-30 to EG-50,

PEG-30 to PEG-50

FOR YOUR SAFETY READ BEFORE OPERATING

OPERATING INSTRUCTIONS

If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS

TO TURN OFF GAS TO THE APPLIANCE

550-223-044(0906)