beautypg.com

Specifications – Watlow MINICHEF 2000 Griddle Applications User Manual

Page 41

background image

4 0

Wa t l o w M

I N I

C

H E F

2 0 0 0

S p e c i f i c a t i o n s

Specifications

(1032)

Control Mode
• Single and dual heat channels, PID or on/off.

1

• Microprocessor-based, programmable, reverse-acting

control outputs.

• User-selectable embedded application software defines

operation of display, keys, inputs, outputs, timing action.

• One-step auto-tuning, WatHelp diagnostics, WatCurve

temperature compensation.

Agency
• CE approved:

89/336/EEC Electromagnetic Compatibility Directive
-EN 50081-1: Emissions
-EN 50082-1: Immunity
73/23/EEC Low-Voltage Directive
-EN 60730-1 and EN 60730-2-9: Safety

• NSF Listed, Criteria 2.

5

• AGA: UL tested to AGA standard Z21.23, UL File

#E43684.

• UL and C-UL recognized, UL 197, 873, 991 and CSA

standard C22.2-24, File # E43684.

Operator Interface
• Membrane overlay, contamination and water resistant,

(supplied by customer).

• LED display, 5-digit, 0.56 in high, red.
• Displays times, temperatures, user prompts and

diagnostic codes.

• User-selectable time and temperature display formats.
• Temperature display formats—˚F or ˚C.
• Time display formats—H:MM:SS, HH:MM, or MMM:SS.
• 8 discrete indicator LEDs, red.
• 6 tactile feedback keys.
• Menu-driven operation and manual modes available.
• WatHelp diagnostics.
• Real-time clock option displays time of day.

Accuracy
• Calibration accuracy and sensor conformity

2

: ± 2.0°F

for Type J thermocouple and RTD, ± 0.35% of span for
Type K and E thermocouples, ±1 LSD, 77°F ± 5°F
ambient and rated line voltage of ±10%.

• Accuracy span: 1000°F (540°C) minimum.
• Temperature stability: ± 0.15˚F/ ˚F (0.15˚C/˚C) change

in ambient typical.

Sensors / Inputs
• Contact inputs, TTL compatible with internal pull-up

resistor, two available.

• Thermocouple,

3

software selectable Type J, K or E,

32 to 1200°F. (Dual-channel applications require at least
one ungrounded thermocouple).

• RTD,

3

2- or 3-wire, platinum, 100, 500, 1000

, at 0°C,

software selectable DIN or JIS curves, 0 to 1200°F
(3-wire will function as 2-wire).

• Input A / D resolution: 15 bit.

Output Options
• Solid-state relay, 0.4A, with or without contact suppres-

sion.

• Switched dc signal, 4.5V to 5.25V, 30mA maximum

output, minimum load resistance > 150

, non-isolated.

Audible Output Options
• Switched dc signal, 4.5V to 5.25V, 30mA maximum

output, minimum load resistance > 150

, non-isolated.

• Internal audible alarm, 75dB at 10 cm.

Connectors
• Sensor Input Terminal Strip

4

: RIACON, 6-position,

quick-connect.

• Power Supply & Input / Output Terminal

4

: AMP,

15-position, quick-connect.

Power / Line Voltage
• 20.4 to 26.4V

Å

(ac), 47 to 63Hz.

• 15VA maximum.
• For CE applications, input power must be limited to

15W external to the control.

• Program retention upon power failure via non-volatile

memory.

• Battery / real-time clock option: 6-year lithium battery,

provides power backup upon power failure, operation
resumption after power recovery, ability to display time
of day.

Operating Environment
• 32 to 176°F (0 to 80°C), 0 to 90% RH, non-condensing.

Storage Temperature
• -40 to 176°F (-40 to 80°C).

Mechanical
• Case: polycarbonate Lexan with adjustable mounting

collar (vertical or horizontal orientation), designed for
mounting on 16-, 18-, 20- and 22-gauge panels.

• Internal panel mounting requires a specified panel

cutout and four #6-32 studs or equivalent.

• Overall width x height x depth: horizontal - 4.13 in x

3.25 in x 2.00 in; vertical - 3.25 in x 4.13 in x 2.00 in
(Assumes mating connectors are attached. Does not
include wire bundle space requirements.).

• Vibration: 2g, 10 to 150Hz, applied in any one of three

axes.

• Weight: 6.50oz maximum.

Program Storage
• All non-embedded user and factory programs are

stored in non-volatile memory. Can be changed by
reprogramming.

Sample/Update Rates
• 1 input: 4Hz.
• 2 inputs: 4Hz.
• PID: 1Hz.
• Control outputs: 100Hz.
• Display: 10Hz.

1

The M

INI

C

HEF

2000 controller is to be used in systems with an

external high temperature limiting device.

2

Thermocouple lead resistance of 200

causes < 1°C error. RTD, 22

gauge wire will not contribute more than 0.086°F error / ft.

3

Dual channel applications require either two thermocouple sen-

sors or two identical RTD sensor types.

4

For mating connector information, see Ordering Information

Accessory section.

5

Certified for thermometer accuracy (oven and hot food holding

applications from 32°F to 60°F) when used with RTD or type J thermo

couple probes.