Configuration Mode Quick Reference

These are the functions, parameters and values included in the Configuration Mode for
this application. You must select Application 21 to access them. For directions, see the
Hardware & Software Setup Guide. The Appendix of that guide includes an explanation
of all parameters and values.

F

unction

Parameter

Value

Your Settings

{Etype} Equipment-Type

[appl`] Application Number

1 - 28

21

[a_Loc] Application Number

Yes, No

Security Lock

[T`OUt] Timer Output

No, Yes

[SEtUP] Setup

[`З_П`] Temperature Display Format

°C or °F

[time] Time Display Format

MMM:SS, HH:MM, H:MM:SS
(H=Hours, M=Minutes, S=Seconds)

[Chirp] Key Chirp

On, Off

[tc```] Thermocouple Type

J, K (shown as [````H]), E

[rtd``] RTD Curve

DIN, JIS

[tconp] WatCurve

TM

Temperature On,

Off

Compensation

[Ofst1] Temperature Offset Channel 1 -99 to 99°F (-55 to 55°C)
[Ofst2] Temperature Offset Channel 2 -99 to 99°F (-55 to 55°C)
[tr`lo] Temperature Range Low

0ºF (-18º C) for rtd inputs,
32ºF (0ºC) for tc inputs to [tr`Hi]

[tr`Hi] Temperature Range High

[tr`lo] to 1200ºF (649ºC)

[ready] Preheat Ready Feature

Yes, No

[rband] Ready Band

1 to 1200°F (649°C)

[Cloc`] Real Time Clock Display

Yes, No

[plOSS] Power Loss Menu Resume

Yes, No

[al``1] Alarms for channel 1

None, Dev, Proc, Both

[aL`P1] Absolute Process Alarm 1

100 to 1200°F (38 to 649°C)

[aLdL1] Low Deviation Alarm 1

-999 to 0°F (-555 to 0°C)

[aLdH1] High Deviation Alarm 1

0 to 999°F (0 to 555°C)

[AL``2] Alarm for channel 2

None, Dev, Proc, Both

[AL`P2] Absolute Process Alarm 2

100 to 1200°F (38 to 649°C)

[aLdL2] Low Deviation Alarm 2

-999 to 0°F (-555 to 0°C)

[aLdH2] High Deviation Alarm 2

0 to 999°F (0 to 555°C)

[tHErl] Thermal

[tyPE`] Temperature Control Type

PID, On-Off

[HYSt1] Hysteresis 1

1 to 99°F (1 to 55°C)

[HYSt2] Hysteresis 2

1 to 99°F (1 to 55°C)

[Pid`U] PID Units

SI, US

[tune1] Auto-tuning 1

on, OFF

[tune2] Auto-tuning 2

on, OFF

[ProP1] Proportional Band 1

1 to 999°F (1 to 555°C)

[rSEt1] Reset (integral) Gain 1

0.00 to 9.99 repeats/minute

[int`1] Integral Gain 1

0.00 to 99.99 minutes/repeat

[rAtE1] Rate (derivative) Gain 1

0.00 to 9.99 minutes

[dEr`1] Derivative Gain 1

0.00 to 9.99 minutes

[CYcL1] PID Cycle Time 1

1 to 60 seconds

[ProP2] Proportional Band 2

1 to 999°F (1 to 555°C)

[rSEt2] Reset (integral) Gain 2

0.00 to 9.99 repeats/minute

[int`2] Integral Gain 2

0.00 to 99.99 minutes/repeat

[rAtE2] Rate (derivative) Gain 2

0.00 to 9.99 minutes

[dEr`2] Derivative Gain 2

0.00 to 9.99 minutes

[CYcL2] PID Cycle Time 2

1 to 60 seconds

`diag] WatHelp

Used for equipment troubleshooting and testing. Not used when programming. See the Hardware

Diagnostics

& Software Setup Guide.