Installation

(Continued)

7. Slope both pipes upward toward

the pump to eliminate trapping
air. If the horizontal distance
exceeds 25 feet, see Chart 2 for the
recommended pipe sizes.

DEEP WELL PUMP WITH HORIZONTAL
AND VERTICAL STORAGE TANK
(FIGURES 6 AND 7)

1. Install the air volume control on the

tank as shown.

2. Connect the copper tube from the

air volume control to the 1/8 in. NPT
opening directly above the 1-1/4 in.
opening on the front of the pump.

3. Install a valve and isolating hose

between the system and the house
plumbing to aid in pump removal
for servicing and for reducing noise
transmitted through the house piping.

4. Provide a hose bib (faucet) at the

lowest point in the system to drain
for service or storage.

DEEP WELL PUMP WITH PRE-CHARGED
STORAGE TANK (FIGURE 8)

1. Check tank pre-charge using a tire

pressure gauge. Set air pressure in
tank to 28 psi which is 2 psi below
pressure switch cut-in level. An air
valve is located on the side and will
accept a standard fitting from a
bicycle pump or air line.

2. Check the pressure with the power

off, faucets open and no water
flowing (zero water pressure).

3. Install a valve and isolator hose between

the system and the house plumbing to
aid in pump removal for servicing and
for reducing noise transmitted to the
house through the piping.

4. Provide a hose bib (faucet) at the

lowest point in the system to drain
for service or storage.

CONVERTING THE DEEP WELL PUMP TO
SHALLOW WELL OPERATION (FIGURE 9)

For shallow wells (25 feet or less), a
bolt-on shallow well jet is available
as an accessory for deep well pumps.
The jet attaches to the front of the
pump with the two bolts provided and
converts the deep well pump into a
shallow well pump. The shallow well
jet has a 1 in. NPT inlet and a 1/8 in.
NPT opening for an air volume control.
For optimum performance, an incline
check valve on the inlet side of the
shallow well jet is recommended.

Electrical

Risk of electrical

shock. This pump is

designed for indoor installation only.

Select the proper size wire and
fuse (Chart 3). Time delay fuses are
recommended over standard fuses
for motor circuit protection. All pump
motors have built-in automatic overload
protection that will prevent damage to
the motor due to overheating.

Do not connect to

electric power supply

until unit is permanently grounded.
Connect ground wire to approved ground
then connect terminal provided.

A metal underground water pipe or
well casing at least 10 feet long makes
the best ground electrode. If plastic
pipe or insulated fittings are used, run
a wire directly to the metal well casing
or use a ground electrode furnished by
the power company.

There is only one proper ground
terminal on the unit. The terminal(s) is
located under the pressure switch cover,
is painted green and is identified as
GRD. The ground connection must be
made at this terminal (Figure 10).

The ground conductor must not be
smaller than the circuit conductors
supplying the motor.

Operating Instructions & Parts Manual

CWS50, CWS75 and CWS100

Figure 6 - Horizontal Tank

To Jet

Air

Volume

Control

Tubing

To Suction

Outlet

Air

Volume

Control

To Drive

Pressure
Switch

Prime
Plug

Figure 7 - Vertical Tank

Outlet

Air Volume

Control Tubing

Hose
Coupling

To Drive

To Jet

Prime To Suction

To
Suction

Air Volume Control

Figure 8 - Pre-charged Storage Tank

Outlet

Prime
Plug

To Drive

To Jet

28-30 psi

3/4 HP an 1 HP

To

Suction

Pressure
Switch

Figure 9 - Shallow Well Jet

To Air Volume
Control

Jet

CHART 3 - RECOMMENDED FUSE AND WIRING DATA - 60 HZ MOTORS

HP

Volt

Dual
Element
Fuse
250V

Distance in Feet

From Meter to Motor

0

51

101

201

to

to to

to

50

100

200

300

Wire Size

1/2

115

15

14

14

12

10

230

10

14

14

14

14

3/4

115

15

14

14

10

8

230

10

14

14

14

14

1

115

20

12

12

10

8

230

10

14

14

14

14

L2

3

L1

1

Figure 10 - Electrical Connections

Line

Motor

Ground
Screw