2. Summary of system equipment
Technical specifications - outdoor units
Rating
hp
5
6
8
10
12
Cooling only model MMY-MAP
0501T8
0601T8
0801T8
1001T8
1201T8
Heat pump model MMY-MAP
0501HT8
0601HT8
0801HT8
1001HT8
1201HT8
Cooling capacity
kW
14.0
16.0
22.4
28.0
33.5
Heating capacity
kW
16.0
18.0
25.0
31.5
37.5
Technical specifications - combination of outdoor units
Rating
hp
5
6
8
10
12
14
16
Cooling only model MMY-MAP
0501T8
0601T8
0801T8
1001T8
1201T8
1401T8
1601T8
Heat pump model MMY-MAP
0501HT8
0601HT8
0801HT8
1001HT8
1201HT8
1401HT8
1601HT8
Cooling capacity
kW
14.0
16.0
22.4
28.0
33.5
38.4
45.0
Heating capacity
kW
16.0
18.0
25.0
31.5
37.5
43.0
50.0
Combined outdoor units
hp
5
6
8
10
12
8
8
-
-
-
-
-
6
8
No. of connectable indoor units
8
10
13
16
20
23
27
Rating
hp
18
20
22
22
24
24
26
Cooling only model MMY-MAP
1801T8
2001T8
2201T8
2211T8
2401T8
2411T8
2601T8
Heat pump model MMY-MAP
1801HT8
2001HT8
2201HT8
2211HT8
2401HT8
2411HT8
2601HT8
Cooling capacity
kW
50.4
56.0
61.5
61.5
68.0
68.0
73.0
Heating capacity
kW
56.5
63.0
69.0
69.0
76.5
76.5
81.5
Combined outdoor units
hp
10
10
8
12
8
12
10
8
10
8
10
8
12
8
-
-
6
-
8
-
8
No. of connectable indoor units
30
33
37
37
40
40
43
Rating
hp
28
30
32
32
34
34
36
Cooling only model MMY-MAP
2801T8
3001T8
3201T8
3211T8
3401T8
3411T8
3601T8
Heat pump model MMY-MAP
2801HT8
3001HT8
3201HT8
3211HT8
3401HT8
3411HT8
3601HT8
Cooling capacity
kW
78.5
84.0
90.0
90.0
96.0
96.0
101.0
Heating capacity
kW
88.0
95.0
100.0
100.0
108.0
108.0
113.0
Combined outdoor units
hp
10
10
8
12
10
12
10
10
10
8
10
8
12
10
8
10
8
10
8
10
8
-
-
8
-
8
-
8
No. of connectable indoor units
47
48
48
48
48
48
48
Rating
hp
36
38
40
42
44
46
48
Cooling only model MMY-MAP
3611T8
3801T8
4001T8
4201T8
4401T8
4601T8
4801T8
Heat pump model MMY-MAP
3611HT8
3801HT8
4001HT8
4201HT8
4401HT8
4601HT8
4801HT8
Cooling capacity
kW
101.0
106.5
112.0
118.0
123.5
130.0
135.0
Heating capacity
kW
113.0
119.5
126.5
132.0
138.0
145.0
150.0
Combined outdoor units
hp
12
10
10
12
12
12
12
12
10
10
10
12
12
12
12
10
10
10
10
12
12
-
8
10
10
10
10
12
No. of connectable indoor units
48
48
48
48
48
48
48
Branching joints and headers
Model
Usage
Appearance
Y-shape branching joint (*3)
RBM-BY53E
Indoor unit capacity code (*1) : Total below 6.4
RBM-BY103E
Indoor unit capacity code (*1) : Total 6.4 or more and below 14.2
(*2)
RBM-BY203E
Indoor unit capacity code (*1) : Total 14.2 or more and below 25.2
(*2)
RBM-BY303E
Indoor unit capacity code (*1) : Total 25.2 or more
(*2)
4-branching header (*4)
RBM-HY1043E Indoor unit capacity code (*1) : Total below 14.2
Max.4
RBM-HY2043E Indoor unit capacity code (*1) : Total 14.2 or more and below 25.2
branches
8-branching header (*4) (*5)
RBM-HY1083E Indoor unit capacity code (*1) : Total below 14.2
Max.8
RBM-HY2083E Indoor unit capacity code (*1) : Total 14.2 or more and below 25.2
branches
T-shape branching joint
RBM-BT13E
1 set of 3 types of T-shape joint pipes as described below:
(For connection of
The required quantity is arranged and they are combined at the site.
outdoor units)
Connection piping
Corresponding dia. (mm)
Q’ty
Balance pipe
Ø3/8”
1
Liquid side piping
Ø3/8” to Ø7/8”
1
Gas side piping
Ø5/8” to Ø1-5/8”
1
*1
The capacity code can be obtained from page 10 (capacity code is not actual capacity).
*2
If total capacity code value of indoor unit exceeds that of outdoor unit, apply capacity code of outdoor unit.
*3
When using Y-shape branching joint for 1st branching, select according to capacity code of outdoor unit.
*4
Max. 6.0 capacity code in total can be connected.
*5 If capacity code of outdoor unit is 26 and more, it is not used for 1st branching.
*6 Model names for outdoor and indoor units described in this guide are shortened because of the space constraints.