Indoor units high-pressure ducted units – Toshiba SUPER MODULAR MULTI HFC R-410A User Manual
Page 50
50
Indoor units
High-pressure ducted units
Model MMD-AP
0181H
0241H
0271H
0361H
0481H
0721H
0961H
Cooling capacity*
kW
5.6
7.1
8.0
11.2
14.0
22.4
28.0
Heating capacity
kW
6.3
8.0
9.0
12.5
16.0
25.0
31.5
Electrical data
Power supply
V-ph-Hz
230-1-50 (voltage range 220-240 V) - power supply to indoor unit only
Operating current
A
0.81
1.35
1.35
1.63
1.84
5.25
5.52
Power input
kW
0.184
0.299
0.299
0.368
0.414
1.200
1.260
Power factor
%
99
96
96
98
98
99
99
Starting current
A
1.3
3.5
3.5
4.1
4.8
13.6
14.8
Unit appearance
Zinc hot dipping steel plate
Unit dimensions
Height
mm
380
380
380
380
380
470
470
Width
mm
850
850
850
850
1200
1380
1380
Depth
mm
660
660
660
660
660
1250
1250
Unit weight
kg
50
52
52
56
67
150
150
Heat exchanger
Finned tube
Sound proofing/heat insulating material
Non-flammable insulation
Fan type
Centrifugal fan
Fan motor power input
W
160
160
160
260
260
370 x 3
370 x 3
Air flow
High
l/s
300
439
439
533
700
1200
1400
Medium
l/s
250
367
367
445
583
1000
1167
Low
l/s
200
295
295
356
467
800
933
Air flow
High
m
3
/h
1080
1580
1580
1920
2520
4320
5040
Medium
m
3
/h
900
1320
1320
1600
2100
3600
4200
Low
m
3
/h
720
1060
1060
1280
1680
2880
3360
Static pressure (factory setting)
Pa
137
137
137
137
137
137
137
Static pressure (low/medium/high)
Pa
68.6/137/196 68.6/137/196 68.6/137/196 68.6/137/196 68.6/137/196 68.6/137/196 68.6/137/196
Sound power level (high)
dB(A)
50
53
53
53
53
62
63
Sound pressure level (high/medium/low)** dB(A)
37/35/33
40/38/36
40/38/36
40/38/36
40/38/36
49/47/45
50/48/46
Air filter
Optional or field-supplied
Controller
Remote controller
Connection pipes
Gas connection diameter
in
1/2
5/8
5/8
5/8
5/8
7/8
7/8
Liquid connection diameter
in
1/4
3/8
3/8
3/8
3/8
1/2
1/2
Drain connection, nom. dia***
in
1
1
1
1
1
1
1
Rated conditions:
Cooling: Indoor air temperature 27°C db/19°C wb, outdoor air temperature 35°C db
Heating: Indoor air temperature 20°C db, outdoor air temperature 7°C db/6°C wb
*
Cooling capacities and electrical data are measured at the conditions specified by JIS B 8615, based on the reference piping which consists of 5 m of main
piping and 2.5 m of branch piping connected with 0 metre height.
**
The sound pressure level is measured in an anechoic chamber in accordance with JIS B 8616. Normally the values measured in the actual operating
environment become larger than the indicated values due to the effects of external sound.
***
Male screw connection one side