CC2420

SWRS041B Page 76 of 89

AGCTST0 (0x24) - AGC Test Register 0

Bit

Field Name

Reset

R/W

Description

15:12 LNAMIX_HYST[3:0]

3

R/W

Hysteresis on the switching between different RF front-end
gain modes, defined in 2 dB steps

11:6 LNAMIX_THR_H[5:0]

25 R/W

Threshold for switching between medium and high RF front-
end gain mode, defined in 2 dB steps

5:0 LNAMIX_THR_L[5:0] 9 R/W

Threshold for switching between low and medium RF front-end
gain mode, defined in 2 dB steps

AGCTST1 (0x25) - AGC Test Register 1

Bit

Field Name

Reset

R/W

Description

15 -

0 W0

Reserved, write as 0

14 AGC_BLANK_MODE

0 R/W

Set the VGA blanking mode when switching out a gain stage

When VGA_GAIN_OE = 0:

0 : Blanking is performed when the AGC algorithm switches
out one or more 14dB gain stages.
1 : Blanking is never performed.

When VGA_GAIN_OE = 1:

Blanking is performed when AGC_BLANK_MODE=1

13 PEAKDET_CUR_BOOST 0 R/W

Doubles the bias current in the peak-detectors in-between the
VGA stages when set.

12:11 AGC_SETTLE_WAIT[1:0] 1

R/W

Timing for AGC to wait for analog gain to settle.

10:8 AGC_PEAK_DET_MODE

[2:0]

0 R/W

Sets the AGC mode for use of the VGA peak detectors:

Bit 2 : Digital ADC peak detector enable / disable
Bit 1 : Analog fixed stages peak detector enable /
disable
Bit 0 : Analog variable gain stage peak detector enable /
disable

7:6 AGC_WIN_SIZE[1:0] 1 R/W

Window size for the accumulate and dump function in the
AGC.

0 : 8 samples
1 : 16 samples
2 : 32 samples
3 : 64 samples

5:0 AGC_REF[5:0]

20 R/W

Target value for the AGC control loop, given in 2 dB steps.
Reset value corresponds to approximately 25% of the ADC
dynamic range in reception.

AGCTST2 (0x26) - AGC Test Register 2

Bit

Field Name

Reset

R/W

Description

15:10 -

0

W0

Reserved, write as 0

9:5 MED2HIGHGAIN[4:0] 9 R/W

MED2HIGHGAIN sets the difference in the receiver
LNA/MIXER gain from medium gain mode to high gain mode,
used by the AGC for setting the correct front-end gain mode.

4:0 LOW2MEDGAIN[4:0]

10 R/W

LOW2MEDGAIN sets the difference in the receiver
LNA/MIXER gain from low gain mode to medium gain mode,
used by the AGC for setting the correct front-end gain mode.