beautypg.com

Receive section, Cc2420 – Texas Instruments 3138 155 232931 User Manual

Page 10

background image

CC2420

SWRS041B Page 10 of 89

6.3 Receive

Section

Parameter

Min.

Typ.

Max.

Unit

Condition / Note

Receiver Sensitivity

-90

-95

dBm

PER = 1%, as specified by [1]

Measured in a 50

Ω single-ended

load through a balun.

[1] requires –85 dBm

Saturation (maximum input level)

0

10

dBm

PER = 1%, as specified by [1]

Measured in a 50

Ω single–ended

load through a balun.

[1] requires –20 dBm

Adjacent channel rejection

+ 5 MHz channel spacing

45

dB

Wanted signal @ -82 dBm,
adjacent modulated channel at
+5 MHz, PER = 1 %, as specified
by [1].

[1] requires 0 dB

Adjacent channel rejection

- 5 MHz channel spacing

30

dB

Wanted signal @ -82 dBm,
adjacent modulated channel at
-5 MHz, PER = 1 %, as specified
by [1].

[1] requires 0 dB

Alternate channel rejection

+ 10 MHz channel spacing

54

dB

Wanted signal @ -82 dBm,
adjacent modulated channel at
+10 MHz, PER = 1 %, as
specified by [1]

[1] requires 30 dB

Alternate channel rejection

- 10 MHz channel spacing

53

dB

Wanted signal @ -82 dBm,
adjacent modulated channel at
-10 MHz, PER = 1 %, as
specified by [1]

[1] requires 30 dB

Channel rejection

≥ + 15 MHz

≤ - 15 MHz

62

62

dB

dB

Wanted signal @ -82 dBm.
Undesired signal is an IEEE
802.15.4 modulated channel,
stepped through all channels
from 2405 to 2480 MHz. Signal
level for PER = 1%.

Co-channel rejection

-3

dB

Wanted signal @ -82 dBm.
Undesired signal is an IEEE
802.15.4 modulated at the same
frequency as the desired signal.
Signal level for PER = 1%.

Blocking / Desensitisation

+/- 5 MHz from band edge
+/- 20 MHz from band edge
+/- 30 MHz from band edge
+/- 50 MHz from band edge

-28
-28
-27
-28

dBm
dBm
dBm
dBm

Wanted signal 3 dB above the
sensitivity level, CW jammer,
PER = 1%. Complies with EN
300 440 class 2.

Spurious emission

30 – 1000 MHz
1 – 12.75 GHz

-73
-58

dBm
dBm

Conducted measurement in a 50
Ω single ended load. Measured
according to EN 300 328, EN 300
440 class 2, FCC CFR47, Part 15
and ARIB STD-T-66