Horizontal Posititon Absolute (HPA)
CSI ... ’
Data Structure
ASCII
CSI n
" ‘ "
[A] set horizontal position absolute
hex.
9B
n
60
dec.
155 n
96
Description
n = 1 (default setting)
=∧
current left margin
This sequence moves the print head to a horizontal print position absolute.
The unit depends on PUM (Positioning Unit Mode) and is either character positions or
defined by the SSU-function (Select Size Unit, see page 8).
Example:
CSI 40 ‘
next character goes to position 40
CSI ‘
next character goes to the left margin
Positions outside the right margin are ignored.