beautypg.com

Csi ... sp u, Csi ... sp v – Tally Genicom Matrix Printer User Manual

Page 249

background image

Set Line Home (SLH)

CSI ... SP U

Set Line Limit (SLL)

CSI ... SP V

Data Structure

ASCII

CSI n

SP

"U"

[A] set line home

hex.

9B

n

20

55

dec.

155 n

32

85

ASCII

CSI n

SP

"V"

[A] set line limit

hex.

9B

n

20

55

dec.

155 n

32

85

Description

n = 1...maximal print area

Default setting: Physical left margin of medium or device.

n specifies the left margin. The first position is 1. The unit depends on PUM (Positioning
Unit Mode) and is either characters or defined by SSU (Select Size Unit, see page 8).

Example:

CSI SP U

reset to physical left margin

CSI 10 SP U

set left margin to position 10

Default setting: Physical right margin (=1) of medium or device.

n specifies the right margin.
The unit depends on PUM (Positioning Unit Mode) and is either character positions or
defined by SSU (Select Size Unit, see page 8).

Example:

CSI SP V

reset to physical right margin

CSI 80 SP V

set right margin to position 80

Paper and Text Formatting

13